SwePub
Sök i LIBRIS databas

  Extended search

id:"swepub:oai:DiVA.org:oru-27174"
 

Search: id:"swepub:oai:DiVA.org:oru-27174" > Flow and peak veloc...

  • 1 of 1
  • Previous record
  • Next record
  •    To hitlist
  • Thunberg, Per,1968-Department of Medical Physics, Örebro University Hospital, Örebro, Sweden (author)

Flow and peak velocity measurements in patients with aortic valve stenosis using phase contrast MR accelerated with k-t BLAST

  • Article/chapterEnglish2012

Publisher, publication year, extent ...

  • Clare, Ireland :Elsevier,2012
  • printrdacarrier

Numbers

  • LIBRIS-ID:oai:DiVA.org:oru-27174
  • https://urn.kb.se/resolve?urn=urn:nbn:se:oru:diva-27174URI
  • https://doi.org/10.1016/j.ejrad.2011.06.034DOI

Supplementary language notes

  • Language:English
  • Summary in:English

Part of subdatabase

Classification

  • Subject category:ref swepub-contenttype
  • Subject category:art swepub-publicationtype

Notes

  • Funding agency:Research Committee of Örebro County Council 
  • Objective: To investigate the accuracy of velocity measurements in patients with aortic valve stenosis using phase contrast (PC) imaging accelerated with SENSE (Sensitivity Encoding) and k-t BLAST (Broad-use Linear Acquisition Speed-up Technique).Methods: Accelerated quantitative breath hold PC measurements, using SENSE and k-t BLAST, were performed in twelve patients whose aortic valve stenosis had been initially diagnosed using echocardiography. Stroke volume (SV) and peak velocity measurements were performed on each subject in three adjacent slices using both accelerating methods.Results: The peak velocities measured with PC MRI using SENSE were -8.0±9.5% lower (p<0.01) compared to the peak velocities measured with k-t BLAST and the correlation was r=0.83. The stroke volumes when using SENSE were slightly higher 0.4±17.1 ml compared to the SV obtained using k-t BLAST but the difference was not significant (p>0.05).Conclusions In this study higher peak velocities were measured in patients with aortic stenosis when combining k-t BLAST with PC MRI compared to PC MRI using SENSE. A probable explanation of this difference is the higher temporal resolution achieved in the k-t BLAST measurement. There was, however, no significant difference between calculated SV based on PC MRI using SENSE and k-t BLAST, respectively.

Subject headings and genre

Added entries (persons, corporate bodies, meetings, titles ...)

  • Emilsson, Kent,1963-Department of Clinical Physiology, Örebro University Hospital, Örebro, Sweden(Swepub:oru)kten (author)
  • Rask, PeterDepartment of Clinical Physiology, Örebro University Hospital, Örebro, Sweden(Swepub:oru)prk (author)
  • Kähäri, AndersDepartment of Radiology, Örebro University Hospital, Örebro, Sweden (author)
  • Department of Medical Physics, Örebro University Hospital, Örebro, SwedenDepartment of Clinical Physiology, Örebro University Hospital, Örebro, Sweden (creator_code:org_t)

Related titles

  • In:European Journal of RadiologyClare, Ireland : Elsevier81:9, s. 2203-22070720-048X1872-7727

Internet link

Find in a library

To the university's database

  • 1 of 1
  • Previous record
  • Next record
  •    To hitlist

Find more in SwePub

By the author/editor
Thunberg, Per, 1 ...
Emilsson, Kent, ...
Rask, Peter
Kähäri, Anders
About the subject
MEDICAL AND HEALTH SCIENCES
MEDICAL AND HEAL ...
and Clinical Medicin ...
and Radiology Nuclea ...
Articles in the publication
European Journal ...
By the university
Örebro University

Search outside SwePub

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Close

Copy and save the link in order to return to this view