SwePub
Sök i LIBRIS databas

  Utökad sökning

WFRF:(Rask Peter)
 

Sökning: WFRF:(Rask Peter) > Estimation of eject...

  • Thunberg, Per,1968-Department of Biomedical Engineering, Örebro University Hospital, Örebro, Sweden (författare)

Estimation of ejection fraction and stroke volume using single- and biplane magnetic resonance imaging of the left cardiac ventricle

  • Artikel/kapitelEngelska2008

Förlag, utgivningsår, omfång ...

  • 2008-11-01
  • London :Taylor & Francis,2008
  • printrdacarrier

Nummerbeteckningar

  • LIBRIS-ID:oai:DiVA.org:oru-3408
  • https://urn.kb.se/resolve?urn=urn:nbn:se:oru:diva-3408URI
  • https://doi.org/10.1080/02841850802415544DOI

Kompletterande språkuppgifter

  • Språk:engelska
  • Sammanfattning på:engelska

Ingår i deldatabas

Klassifikation

  • Ämneskategori:vet swepub-contenttype
  • Ämneskategori:art swepub-publicationtype

Anmärkningar

  • Background: In cardiac magnetic resonance imaging (MRI), left ventricular stroke volume (SV) and ejection fractions (EF) are occasionally calculated using single-plane and biplane ellipsoid models. In previous studies, the calculated SV and EF using single- and biplane ellipsoid models have been compared to reference values calculated from short-axis (SA) images. In these studies, however, it has been emphasized that through-plane motion of the basal SA images represents an important source of error, which may result in incorrect reference values.Purpose: To compare the calculated SV and EF using single-plane and biplane ellipsoid models with SV and EF calculated from SA images in which compensation was made for through-plane motion.Material and Methods: A group of 20 patients who underwent MRI examination were included in the study. SV and EF were calculated using the stack of SA images (which had been compensated for through-plane motion) and compared to the SV and EF calculated according to the single- and biplane ellipsoid models.Results: The mean difference between the single-plane model and the reference was -0.3±6.5 for EF and 7.2±17.1 ml for SV. Corresponding comparison between the biplane method and the reference resulted in a mean difference of 0.3±6.1 for EF and 11.8±14.9 ml for SV.Conclusion: The results from this study show that left ventricular EF can be adequately estimated using the single- and biplane ellipsoid models, while SV tends to be overestimated using both geometrical models

Ämnesord och genrebeteckningar

Biuppslag (personer, institutioner, konferenser, titlar ...)

  • Emilsson, Kent,1963-Örebro universitet,Hälsoakademin,Department of Clinical Physiology, Örebro University Hospital, Örebro, Sweden(Swepub:oru)kten (författare)
  • Rask, PeterDepartment of Radiology, Örebro University Hospital, Örebro, Sweden(Swepub:oru)prk (författare)
  • Kähäri, AndersDepartment of Radiology, Örebro University Hospital, Örebro, Sweden (författare)
  • Department of Biomedical Engineering, Örebro University Hospital, Örebro, SwedenHälsoakademin (creator_code:org_t)

Sammanhörande titlar

  • Ingår i:Acta RadiologicaLondon : Taylor & Francis49:9, s. 1016-10230284-18511600-0455

Internetlänk

Hitta via bibliotek

Till lärosätets databas

Hitta mer i SwePub

Av författaren/redakt...
Thunberg, Per, 1 ...
Emilsson, Kent, ...
Rask, Peter
Kähäri, Anders
Om ämnet
MEDICIN OCH HÄLSOVETENSKAP
MEDICIN OCH HÄLS ...
och Klinisk medicin
och Kardiologi
Artiklar i publikationen
Acta Radiologica
Av lärosätet
Örebro universitet

Sök utanför SwePub

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Stäng

Kopiera och spara länken för att återkomma till aktuell vy