SwePub
Sök i LIBRIS databas

  Utökad sökning

L773:1879 0887 OR L773:0167 8140
 

Sökning: L773:1879 0887 OR L773:0167 8140 > Quantitative assess...

Quantitative assessment of skin erythema following breast cancer RT

Wengström, Yvonne, 1959- (författare)
Division of Nursing Research at Karolinska Hospital, Department of Medicine, Karolinska Institutet, Stockholm,Sweden
Forsberg, Christina (författare)
2Karolinska Insitute, Dep of Surgery, Stockholm, Sweden
Näslund, I. (författare)
1Karolinska Institutet, Radiotherapy, Stockholm, Sweden
visa fler...
Bergh, J. (författare)
3Karolinska Institute, Dep of oncology, Stockholm, Sweden
visa färre...
 (creator_code:org_t)
2003
2003
Engelska.
Ingår i: Radiotherapy and Oncology. - 0167-8140 .- 1879-0887. ; 68, s. S20-S20
  • Tidskriftsartikel (refereegranskat)
Abstract Ämnesord
Stäng  
  • Visual assessment is the most common clinical investigation of skin reactions in radiotherapy. Due to the unquantitative and subjective nature of this method additional non-invasive methods are needed for more accurate evaluation of the visible acute adverse skin reactions due to radiotherapy• The purpose of this study was to evaluate a new objective measure with regard to reliability and validity and compare it with an established objective measure and a visual assessment.Material and Methods: A sample of fifty-three consecutive patients commencing curative tangential radiation therapy to the breast parenchyma was included in the study• The skin area of the treated breast was divided into five sections and assessed individually at 0 Gy, 24 Gy and 50 Gy. The RTOG scoring system was used for the visual assessment of the skin reactions. The first objective measure included reflectance spectrometry (DermaSpectrometer) measures at fixed points within the treatment area. For the second objective measure digital images were taken with a system using a digital camera and software. The images were analyzed using the Adobe Photoshop 5•0 software program•Results: The results provided significant evidence of the test-retest reliability of the camera• The correlation between the objective measures proved to be significant as the treatment progressed• The results suggest that the Camera may be used in a reliable and valid way to measure skin erythema due to radiotherapy•

Ämnesord

MEDICIN OCH HÄLSOVETENSKAP  -- Hälsovetenskap -- Omvårdnad (hsv//swe)
MEDICAL AND HEALTH SCIENCES  -- Health Sciences -- Nursing (hsv//eng)

Nyckelord

Oncology; Radiology
Nuclear Medicine
Medical Imaging
Vårdvetenskap
Nursing Science

Publikations- och innehållstyp

ref (ämneskategori)
art (ämneskategori)

Hitta via bibliotek

Till lärosätets databas

Hitta mer i SwePub

Av författaren/redakt...
Wengström, Yvonn ...
Forsberg, Christ ...
Näslund, I.
Bergh, J.
Om ämnet
MEDICIN OCH HÄLSOVETENSKAP
MEDICIN OCH HÄLS ...
och Hälsovetenskap
och Omvårdnad
Artiklar i publikationen
Radiotherapy and ...
Av lärosätet
Örebro universitet

Sök utanför SwePub

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Stäng

Kopiera och spara länken för att återkomma till aktuell vy