SwePub
Sök i LIBRIS databas

  Utökad sökning

WFRF:(Geijer Håkan)
 

Sökning: WFRF:(Geijer Håkan) > Assessment of left ...

Assessment of left ventricular function from M-mode measurement of circumflex artery motion recorded by coronary angiography.

Kähäri, Anders (författare)
Department of Radiology, Örebro University Hospital, Örebro, Sweden
Thunberg, Per, 1968- (författare)
Department of Biomedical Engineering, Örebro University Hospital, Örebro, Sweden
Emilsson, Kent, 1963- (författare)
Örebro universitet,Institutionen för hälsovetenskap och medicin,Department of Clinical Physiology, Karlskoga Hospital, Karlskoga, Sweden
visa fler...
Geijer, Håkan, 1961- (författare)
Department of Radiology, Örebro University Hospital, Örebro, Sweden
Andersson, Torbjörn, 1948- (författare)
Department of Radiology, Örebro University Hospital, Örebro, Sweden
Wandt, Birger, 1951- (författare)
Department of Clinical Physiology, Sahlgrenska University Hospital, Gothenburg, Sweden
visa färre...
 (creator_code:org_t)
2009-07-12
2003
Engelska.
Ingår i: Scandinavian Cardiovascular Journal. - : Informa Healthcare. - 1401-7431 .- 1651-2006. ; 37:5, s. 259-265
  • Tidskriftsartikel (refereegranskat)
Abstract Ämnesord
Stäng  
  • OBJECTIVE: To evaluate the usefulness of M-mode measurement of circumflex artery motion (CAM) for assessment of left ventricular (LV) function.DESIGN: Seventy-two patients referred for coronary angiography and LV angiography were included. Ejection fraction (EF) was calculated from LV angiography and systolic and diastolic parameters of CAM were measured by M-mode from coronary angiography. Twenty-three patients, examined by echocardiography of mitral annulus motion (MAM) within 24 h before the angiographic examination, formed a subgroup for comparison between angiographic M-mode of CAM and echocardiographic M-mode of MAM.RESULTS: In addition to previous reported CAM amplitude and longitudinal fractional shortening (FSL) the maximal systolic velocity of CAM can be reliably recorded by M-mode. The diastolic indices, atrial contribution to the total amplitude and maximal early and late diastolic velocities, are also well monitored by M-mode of CAM in comparison with echocardiographic MAM.CONCLUSION: LV systolic and diastolic function can be assessed by M-mode of CAM.

Ämnesord

MEDICIN OCH HÄLSOVETENSKAP  -- Klinisk medicin -- Kardiologi (hsv//swe)
MEDICAL AND HEALTH SCIENCES  -- Clinical Medicine -- Cardiac and Cardiovascular Systems (hsv//eng)

Nyckelord

atrioventricular plane displacement
circumflex artery motion
coronary angiography
left ventricular function
mitral annulus motion
M‐mode Read More: http://informahealthcare.com/doi/abs/10.1080/14017430310001708
Cardiology
Kardiologi
MEDICINE

Publikations- och innehållstyp

ref (ämneskategori)
art (ämneskategori)

Hitta via bibliotek

Till lärosätets databas

Sök utanför SwePub

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Stäng

Kopiera och spara länken för att återkomma till aktuell vy