SwePub
Sök i LIBRIS databas

  Utökad sökning

WFRF:(Geijer Håkan)
 

Sökning: WFRF:(Geijer Håkan) > Low dose CT of the ...

Low dose CT of the lumbar spine compared with radiography : a study on image quality with implications for clinical practice

Alshamari, Muhammed, 1975- (författare)
Örebro University,Örebro universitet,Institutionen för hälsovetenskap och medicin,Department of Radiology, Faculty of Health and Medical Sciences, Örebro University, Örebro, Sweden,Radiologi
Geijer, Mats, 1957- (författare)
Lund University,Lunds universitet,Diagnostisk radiologi, Lund,Sektion V,Institutionen för kliniska vetenskaper, Lund,Medicinska fakulteten,Diagnostic Radiology, (Lund),Section V,Department of Clinical Sciences, Lund,Faculty of Medicine,Skåne University Hospital
Norrman, Eva, 1966- (författare)
Örebro University,Örebro universitet,Institutionen för hälsovetenskap och medicin,Department of Medical Physics,, Faculty of Health and Medical Sciences, Örebro University, Örebro, Sweden
visa fler...
Lidén, Mats, 1976- (författare)
Örebro University,Örebro universitet,Institutionen för hälsovetenskap och medicin,Department of Radiology, Faculty of Health and Medical Sciences, Örebro University, Örebro, Sweden,Radiologi
Krauss, Wolfgang, 1973- (författare)
Örebro University,Örebro universitet,Institutionen för hälsovetenskap och medicin,Department of Radiology, Faculty of Health and Medical Sciences, Örebro University, Örebro, Sweden,Radiologi
Wilamowski, Franciszek (författare)
Örebro University
Geijer, Håkan, 1961- (författare)
Örebro University,Örebro universitet,Institutionen för hälsovetenskap och medicin,Department of Radiology, Faculty of Health and Medical Sciences, Örebro University, Örebro, Sweden,Radiologi
visa färre...
 (creator_code:org_t)
2015-07-27
2016
Engelska.
Ingår i: Acta Radiologica. - London, United Kingdom : Sage Publications. - 0284-1851 .- 1600-0455. ; 57:5, s. 602-611
  • Tidskriftsartikel (refereegranskat)
Abstract Ämnesord
Stäng  
  • Background: Lumbar spine radiography is often performed instead of CT for radiation dose concerns.Purpose: To compare image quality and diagnostic information from low dose lumbar spine CT at an effective dose of about 1 mSv with lumbar spine radiography.Material and Methods: Fifty-one patients were examined by both methods. Five reviewers scored all examinations on eight image quality criteria using a five-graded scale and also assessed three common pathologic changes.Results: Low dose CT scored better than radiography on the following: sharp reproduction of disc profile and vertebral end-plates (odds ratio [OR], 1.8; 95% confidence interval [CI], 1.3-2.5), intervertebral foramina and pedicles (OR, 4.3; 95% CI, 3.1-5.9), intervertebral joints (OR, 139; 95% CI, 59-326), spinous and transverse processes (OR, 7.0; 95% CI, 4.3-11.2), sacro-iliac joints (OR, 4.2; 95% CI, 3.2-5.7), reproduction of the adjacent soft tissues (OR, 2.9; 95% CI, 2.1-4.0), and absence of any obscuring superimposed gastrointestinal gas and contents (OR, 188; 95% CI, 66-539). Radiography scored better on sharp reproduction of cortical and trabecular bone (OR, 0.3; 95% CI, 0.2-0.4). The reviewers visualized disk degeneration, spondylosis/diffuse idiopathic skeletal hyperostosis (DISH) and intervertebral joint osteoarthritis more clearly and were more certain with low dose CT. Mean time to review low dose CT was 204 s (95% CI, 194-214 s.), radiography 152 s (95% CI, 146-158 s.). The effective dose for low dose CT was 1.0-1.1 mSv, for radiography 0.7 mSv.Conclusion: Low dose lumbar spine CT at about 1 mSv has superior image quality to lumbar spine radiography with more anatomical and diagnostic information.

Ämnesord

MEDICIN OCH HÄLSOVETENSKAP  -- Klinisk medicin -- Radiologi och bildbehandling (hsv//swe)
MEDICAL AND HEALTH SCIENCES  -- Clinical Medicine -- Radiology, Nuclear Medicine and Medical Imaging (hsv//eng)

Nyckelord

Radiation dose
radiography
tomography
X-ray computed
axial skeleton
Radiology
Radiologi

Publikations- och innehållstyp

ref (ämneskategori)
art (ämneskategori)

Hitta via bibliotek

Till lärosätets databas

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Stäng

Kopiera och spara länken för att återkomma till aktuell vy