Search: L773:1435 4373 OR L773:0934 9723 >
Rapid identificatio...
Rapid identification of Streptococcus pneumoniae in blood cultures by using the ImmuLex, Slidex and Wellcogen latex agglutination tests and the BinaxNOW antigen test
-
- Altun, O. (author)
- Karolinska Institutet
-
- Athlin, Simon, 1971- (author)
- Örebro universitet,Institutionen för medicinska vetenskaper,Department of Infectious Diseases, Örebro University, Örebro, Sweden
-
- Almuhayawi, M. (author)
- Karolinska Institutet
-
show more...
-
- Strålin, K. (author)
- Karolinska Institutet
-
- Özenci, V. (author)
- Karolinska Institutet
-
show less...
-
(creator_code:org_t)
- 2016-01-21
- 2016
- English.
-
In: European Journal of Clinical Microbiology and Infectious Diseases. - : Springer-Verlag New York. - 0934-9723 .- 1435-4373. ; 35:4, s. 579-585
- Related links:
-
https://urn.kb.se/re...
-
show more...
-
https://doi.org/10.1...
-
http://kipublication...
-
show less...
Abstract
Subject headings
Close
- Rapid identification of Streptococcus pneumoniae in blood culture (BC) bottles is important for early directed antimicrobial therapy in pneumococcal bacteraemia. We evaluated a new latex agglutination (LA) test on BC bottles, the ImmuLex™ S. pneumoniae Omni (Statens Serum Institut, Denmark), and compared the performance with the Slidex® pneumo-Kit (bioMérieux, France) and the Wellcogen™ S. pneumoniae (Remel, UK) LA tests, as well as the BinaxNOW® S. pneumoniae (Alere, USA) antigen test. The four tests were directly applied on 358 positive BC bottles with Gram-positive cocci in pairs or chains and on 15 negative bottles. Valid test results were recorded in all cases for ImmuLex and BinaxNOW and in 88.5 % (330/373) and 94.1 % (351/373) of cases for Slidex and Wellcogen, respectively. Based on bottles positive for S. pneumoniae by conventional methods, the sensitivity of ImmuLex was 99.6 %, similar to the other tests (range, 99.6-100 %). Based on bottles positive for non-pneumococcal pathogens, the specificity of ImmuLex was 82.6 %, in comparison to 97.6 % for Slidex (p < 0.01) and 85.4 % for Wellcogen (p = ns). The BinaxNOW test had a lower specificity (64.1 %) than any LA test (p < 0.01). On BC bottles positive for α-haemolytic streptococci, ImmuLex was positive in 12/67 (17.9 %) cases, Slidex in 2/59 (3.4 %) cases, Wellcogen in 11/64 (17.2 %) cases and BinaxNOW in 25/67 (37.3 %) cases. In conclusion, the ImmuLex test provides a valid and sensitive technique for the rapid detection of S. pneumoniae in BC bottles, similar to the other compared methods. However, the specificity was sub-optimal, since the test may cross-react with other Gram-positive bacteria.
Subject headings
- MEDICIN OCH HÄLSOVETENSKAP -- Klinisk medicin -- Infektionsmedicin (hsv//swe)
- MEDICAL AND HEALTH SCIENCES -- Clinical Medicine -- Infectious Medicine (hsv//eng)
- MEDICIN OCH HÄLSOVETENSKAP -- Medicinsk bioteknologi -- Biomedicinsk laboratorievetenskap/teknologi (hsv//swe)
- MEDICAL AND HEALTH SCIENCES -- Medical Biotechnology -- Biomedical Laboratory Science/Technology (hsv//eng)
Keyword
- Infektionssjukdomar
- Infectious Diseases
Publication and Content Type
- ref (subject category)
- art (subject category)
Find in a library
To the university's database