SwePub
Sök i LIBRIS databas

  Extended search

WFRF:(Barth Henrik)
 

Search: WFRF:(Barth Henrik) > A cross-linked hyal...

A cross-linked hyaluronic acid hydrogel (Healaflow(®)) as a novel vitreous substitute

Barth, Henrik (author)
Lund University,Lunds universitet,Oftalmologi, Lund,Sektion IV,Institutionen för kliniska vetenskaper, Lund,Medicinska fakulteten,Ophthalmology, Lund,Section IV,Department of Clinical Sciences, Lund,Faculty of Medicine
Crafoord, Sven, 1950- (author)
Örebro universitet,Institutionen för medicinska vetenskaper,Department of Ophthalmology, Örebro University Hospital, Örebro, Sweden
Andréasson, Sten (author)
Lund University,Lunds universitet,Oftalmologi, Lund,Sektion IV,Institutionen för kliniska vetenskaper, Lund,Medicinska fakulteten,Ophthalmology, Lund,Section IV,Department of Clinical Sciences, Lund,Faculty of Medicine
show more...
Ghosh, Fredrik (author)
Lund University,Lunds universitet,Oftalmologi, Lund,Sektion IV,Institutionen för kliniska vetenskaper, Lund,Medicinska fakulteten,Ophthalmology, Lund,Section IV,Department of Clinical Sciences, Lund,Faculty of Medicine
show less...
 (creator_code:org_t)
2016-01-08
2016
English.
In: Graefe's Archives for Clinical and Experimental Ophthalmology. - : Springer. - 0721-832X .- 1435-702X. ; 254:4, s. 697-703
  • Journal article (peer-reviewed)
Abstract Subject headings
Close  
  • Purpose: Vitrectomy requires the substitution of the natural vitreous, as well as tamponading of retinal breaks. Clinically available alternatives such as gas and silicone oil have side effects such as inflammation, secondary glaucoma, cataract, and a need for head posturing. In this study, a hydrogel of cross-linked sodium hyaluronic acid (Healaflow(®)) is evaluated for use as a novel vitreous substitute.Methods: A combined 25-20-gauge pars plana vitrectomy with posterior vitreous detachment was performed in the right eye of twelve pigmented rabbits, with subsequent injection of approximately 1 ml Healaflow(®). Clinical evaluation, measurement of intraocular pressure (IOP), and full-field ERG were performed postoperatively. The rabbits were sacrificed at different time-points between 42 and 105 days. After enucleation, the eyes were examined macroscopically, photographed, and prepared for histological examination with routine microscopy and immunohistochemistry.Results: Healaflow(®) was successfully used with standard surgical procedures and remained translucent but did lose most of its viscosity during the postoperative period. One rabbit was lost due to unrelated causes. In two eyes iatrogenic partial retinal detachments were seen, and in two eyes significant cataract developed due to intra-operative complications. ERG-recordings revealed no toxic effect on rod or cone function. Routine microscopy and immunohistochemistry demonstrated normal morphology with some Müller cell activation (up-regulation of glial acidic fibrillary protein, GFAP) compared to unoperated eyes and no significant DNA-fragmentation (TUNEL-assay).Conclusions: Healaflow® did not affect retinal morphology or function negatively during long-term use as a vitreous substitute, making it highly interesting in this setting. An estimated retention time of a few weeks suggests potential for use as a short-term tamponade. Future work will include an increased ratio of cross-linking to prolong the structural integrity of the gel.

Subject headings

MEDICIN OCH HÄLSOVETENSKAP  -- Klinisk medicin -- Oftalmologi (hsv//swe)
MEDICAL AND HEALTH SCIENCES  -- Clinical Medicine -- Ophthalmology (hsv//eng)

Keyword

Vitreous substitute
vitreoretinal surgery
hyaluronic acid
immunohistochemistry

Publication and Content Type

ref (subject category)
art (subject category)

Find in a library

To the university's database

Find more in SwePub

By the author/editor
Barth, Henrik
Crafoord, Sven, ...
Andréasson, Sten
Ghosh, Fredrik
About the subject
MEDICAL AND HEALTH SCIENCES
MEDICAL AND HEAL ...
and Clinical Medicin ...
and Ophthalmology
Articles in the publication
Graefe's Archive ...
By the university
Örebro University
Lund University

Search outside SwePub

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Close

Copy and save the link in order to return to this view