Search: WFRF:(Norrman Eva)
> (2015-2019) >
Impact of iterative...
Impact of iterative reconstruction on image quality of low-dose CT of the lumbar spine
-
- Alshamari, Muhammed, 1975- (author)
- Örebro University,Örebro universitet,Institutionen för medicinska vetenskaper,Region Örebro län,Department of Radiology, Örebro University Hospital, Örebro, Sweden
-
- Geijer, Mats, 1957- (author)
- Örebro University,Lund University,Lunds universitet,Örebro universitet,Institutionen för medicinska vetenskaper,Region Örebro län,Department of Radiology, Örebro University Hospital, Örebro, Sweden; Department of Medical Imaging and Physiology, Skåne University Hospital, Lund University, Lund, Sweden,Diagnostisk radiologi, Lund,Sektion V,Institutionen för kliniska vetenskaper, Lund,Medicinska fakulteten,Diagnostic Radiology, (Lund),Section V,Department of Clinical Sciences, Lund,Faculty of Medicine
-
- Norrman, Eva, 1966- (author)
- Örebro University,Örebro universitet,Institutionen för medicinska vetenskaper,Region Örebro län,Department of Medical Physics, Örebro University Hospital, Örebro, Sweden
-
show more...
-
- Lidén, Mats, 1976- (author)
- Örebro University,Örebro universitet,Institutionen för medicinska vetenskaper,Region Örebro län,Department of Radiology, Örebro University Hospital, Örebro, Sweden
-
- Krauss, Wolfgang, 1973- (author)
- Örebro University,Örebro universitet,Institutionen för medicinska vetenskaper,Region Örebro län,Department of Radiology, Örebro University Hospital, Örebro, Sweden
-
- Jendeberg, Johan, 1972- (author)
- Örebro University,Örebro universitet,Institutionen för medicinska vetenskaper,Region Örebro län,Department of Radiology, Örebro University Hospital, Örebro, Sweden
-
- Magnuson, Anders (author)
- Örebro University
-
- Geijer, Håkan, 1961- (author)
- Örebro University,Örebro universitet,Institutionen för medicinska vetenskaper,Region Örebro län,Department of Radiology, Örebro University Hospital, Örebro, Sweden
-
show less...
-
(creator_code:org_t)
- 2016-11-14
- 2017
- English.
-
In: Acta Radiologica. - London : Sage Publications. - 0284-1851 .- 1600-0455. ; 58:6, s. 702-709
- Related links:
-
http://dx.doi.org/10...
-
show more...
-
https://urn.kb.se/re...
-
https://doi.org/10.1...
-
https://lup.lub.lu.s...
-
show less...
Abstract
Subject headings
Close
- Background: Iterative reconstruction (IR) is a recent reconstruction algorithm for computed tomography (CT) that can be used instead of the standard algorithm, filtered back projection (FBP), to reduce radiation dose and/or improve image quality.Purpose: To evaluate and compare the image quality of low-dose CT of the lumbar spine reconstructed with IR to conventional FBP, without further reduction of radiation dose.Material and Methods: Low-dose CT on 55 patients was performed on a Siemens scanner using 120 kV tube voltage, 30 reference mAs, and automatic dose modulation. From raw CT data, lumbar spine CT images were reconstructed with a medium filter (B41f) using FBP and four levels of IR (levels 2-5). Five reviewers scored all images on seven image quality criteria according to the European guidelines on quality criteria for CT, using a five-grade scale. A side-by-side comparison was also performed.Results: There was significant improvement in image quality for IR (levels 2-4) compared to FBP. According to visual grading regression, odds ratios of all criteria with 95% confidence intervals for IR2, IR3, IR4, and IR5 were: 1.59 (1.39-1.83), 1.74 (1.51-1.99), 1.68 (1.46-1.93), and 1.08 (0.94-1.23), respectively. In the side-by-side comparison of all reconstructions, images with IR (levels 2-4) received the highest scores. The mean overall CTDIvol was 1.70 mGy (SD 0.46; range, 1.01-3.83 mGy). Image noise decreased in a linear fashion with increased strength of IR.Conclusion: Iterative reconstruction at levels 2, 3, and 4 improves image quality of low-dose CT of the lumbar spine compared to FPB.
Subject headings
- MEDICIN OCH HÄLSOVETENSKAP -- Klinisk medicin -- Radiologi och bildbehandling (hsv//swe)
- MEDICAL AND HEALTH SCIENCES -- Clinical Medicine -- Radiology, Nuclear Medicine and Medical Imaging (hsv//eng)
- TEKNIK OCH TEKNOLOGIER -- Medicinteknik -- Medicinsk bildbehandling (hsv//swe)
- ENGINEERING AND TECHNOLOGY -- Medical Engineering -- Medical Image Processing (hsv//eng)
Keyword
- X-ray computed tomography (CT)
- image manipulation/reconstruction
- lumbar vertebrae
- radiation dosage
- spine
- Journal Article
Publication and Content Type
- ref (subject category)
- art (subject category)
Find in a library
To the university's database
- By the author/editor
-
Alshamari, Muham ...
-
Geijer, Mats, 19 ...
-
Norrman, Eva, 19 ...
-
Lidén, Mats, 197 ...
-
Krauss, Wolfgang ...
-
Jendeberg, Johan ...
-
show more...
-
Magnuson, Anders
-
Geijer, Håkan, 1 ...
-
show less...
- About the subject
-
- MEDICAL AND HEALTH SCIENCES
-
MEDICAL AND HEAL ...
-
and Clinical Medicin ...
-
and Radiology Nuclea ...
-
- ENGINEERING AND TECHNOLOGY
-
ENGINEERING AND ...
-
and Medical Engineer ...
-
and Medical Image Pr ...
- Articles in the publication
-
Acta Radiologica
- By the university
-
Örebro University
-
Lund University