SwePub
Sök i LIBRIS databas

  Extended search

WFRF:(Thunberg Per 1968 )
 

Search: WFRF:(Thunberg Per 1968 ) > Metal artifacts in ...

Metal artifacts in computed tomography : impact of reduction methods on image quality and radiotherapy treatment planning

Andersson, Karin, 1989- (author)
Örebro universitet,Institutionen för medicinska vetenskaper
Thunberg, Per, docent, 1968- (thesis advisor)
Örebro universitet,Institutionen för medicinska vetenskaper
Norrman, Eva, 1966- (thesis advisor)
Örebro universitet,Institutionen för medicinska vetenskaper,Region Örebro län
show more...
Persliden, Jan, adjungerad professor (thesis advisor)
Region Örebro Län
Tingberg, Anders, docent (opponent)
Strålfysik, Malmö, Skånes universitetssjukhus
show less...
 (creator_code:org_t)
ISBN 9789175292281
Örebro : Örebro University, 2018
English 81 s.
Series: Örebro Studies in Medicine, 1652-4063 ; 172
  • Doctoral thesis (other academic/artistic)
Abstract Subject headings
Close  
  • Degradation of image quality by metal artifacts is a common problem in computed tomography (CT) imaging, which can limit the diagnostic value of a CT examination and also introduce inaccuracies in radiotherapy (RT) treatment planning. In recent years, commercial metal artifact reduction (MAR) methods have been launched by several CT vendors. The overall aim of this thesis was to evaluate MAR methods in diagnostic imaging and RT treatment planning.Evaluations of hip prosthesis phantom CT images showed that MAR algorithms in general improved image quality, based on both visual grading analysis and quantitative measures, while the application of virtual monoenergetic reconstructions insufficiently reduced metal artifacts. In some cases additional artifacts were introduced by the MAR algorithms. MAR algorithms were also evaluated in hip prosthesis phantom CT imaging used for proton therapy treatment planning, where improvements in dose calculation accuracy were observed.Studies of Head & Neck (H&N) implant CT images in RT treatment planning were also performed. By visual grading of anatomy visualization with respect to target delineation in dental implant patient images, MAR algorithms were shown to significantly improve image quality. However, only minor effects of H&N implant artifacts on proton dose distributions were seen. The impact might be greater for more severe artifacts than those studied here, and thus further investigations of such cases are needed.In conclusion, MAR algorithms have been shown to enhance image quality for diagnostic applications and to improve anatomy visualization in RT treatment planning. The MAR algorithms led to increased proton dose calculation accuracy in some cases, while in other situations only minor changes were seen.

Subject headings

MEDICIN OCH HÄLSOVETENSKAP  -- Klinisk medicin -- Kirurgi (hsv//swe)
MEDICAL AND HEALTH SCIENCES  -- Clinical Medicine -- Surgery (hsv//eng)

Keyword

computed tomography
metal artifacts
image quality
visual grading analysis
radiotherapy
proton therapy
hip prosthesis
dental implants

Publication and Content Type

vet (subject category)
dok (subject category)

Find in a library

To the university's database

Search outside SwePub

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Close

Copy and save the link in order to return to this view