Sökning: WFRF:(Nyman Tuula A.) >
A comparative evalu...
A comparative evaluation of software for the analysis of liquid chromatography-tandem mass spectrometry data from isotope coded affinity tag experiments
-
- Moulder, Robert (författare)
- Turku Centre for Biotechnology, University of Turku and Åbo Akademi University, Turku, Finland
-
- Filén, Jan-Jonas (författare)
- Turku Centre for Biotechnology, University of Turku and Åbo Akademi University, Turku, Finland; The National Graduate School in Informational and Structural Biology, Finland
-
- Salmi, Jussi (författare)
- Department of Information Technology and Turku Centre for Computer Science, Turku, Finland
-
visa fler...
-
- Katajamaa, Mikko (författare)
- Turku Centre for Biotechnology, University of Turku and Åbo Akademi University, Turku, Finland
-
- Nevalainen, Olli S. (författare)
- Department of Information Technology and Turku Centre for Computer Science, Turku, Finland
-
- Oresic, Matej, 1967- (författare)
- VTT Biotechnology, Espoo, Finland
-
- Aittokallio, Tero (författare)
- Department of Mathematics, University of Turku, Finland
-
- Lahesmaa, Riitta (författare)
- Turku Centre for Biotechnology, University of Turku and Åbo Akademi University, Turku, Finland
-
Nyman, Tuula A. (författare)
-
visa färre...
-
(creator_code:org_t)
- Wiley-VCH Verlagsgesellschaft, 2005
- 2005
- Engelska.
-
Ingår i: Proteomics. - : Wiley-VCH Verlagsgesellschaft. - 1615-9853 .- 1615-9861. ; 5:11, s. 2748-2760
- Relaterad länk:
-
https://urn.kb.se/re...
-
visa fler...
-
https://doi.org/10.1...
-
visa färre...
Abstract
Ämnesord
Stäng
- The options available for processing quantitative data from isotope coded affinity tag (ICAT) experiments have mostly been confined to software specific to the instrument of acquisition. However, recent developments with data format conversion have subsequently increased such processing opportunities. In the present study, data sets from ICAT experiments, analysed with liquid chromatography/tandem mass spectrometry (MS/MS), using an Applied Biosystems QSTAR Pulsar quadrupole-TOF mass spectrometer, were processed in triplicate using separate mass spectrometry software packages. The programs Pro ICAT, Spectrum Mill and SEQUEST with XPRESS were employed. Attention was paid towards the extent of common identification and agreement of quantitative results, with additional interest in the flexibility and productivity of these programs. The comparisons were made with data from the analysis of a specifically prepared test mixture, nine proteins at a range of relative concentration ratios from 0.1 to 10 (light to heavy labelled forms), as a known control, and data selected from an ICAT study involving the measurement of cytokine induced protein expression in human lymphoblasts, as an applied example. Dissimilarities were detected in peptide identification that reflected how the associated scoring parameters favoured information from the MS/MS data sets. Accordingly, there were differences in the numbers of peptides and protein identifications, although from these it was apparent that both confirmatory and complementary information was present. In the quantitative results from the three programs, no statistically significant differences were observed.
Ämnesord
- NATURVETENSKAP -- Biologi -- Bioinformatik och systembiologi (hsv//swe)
- NATURAL SCIENCES -- Biological Sciences -- Bioinformatics and Systems Biology (hsv//eng)
Publikations- och innehållstyp
- ref (ämneskategori)
- art (ämneskategori)
Hitta via bibliotek
Till lärosätets databas
- Av författaren/redakt...
-
Moulder, Robert
-
Filén, Jan-Jonas
-
Salmi, Jussi
-
Katajamaa, Mikko
-
Nevalainen, Olli ...
-
Oresic, Matej, 1 ...
-
visa fler...
-
Aittokallio, Ter ...
-
Lahesmaa, Riitta
-
Nyman, Tuula A.
-
visa färre...
- Om ämnet
-
- NATURVETENSKAP
-
NATURVETENSKAP
-
och Biologi
-
och Bioinformatik oc ...
- Artiklar i publikationen
-
Proteomics
- Av lärosätet
-
Örebro universitet