SwePub
Sök i LIBRIS databas

  Utökad sökning

WFRF:(Geijer Håkan)
 

Sökning: WFRF:(Geijer Håkan) > The no-touch saphen...

The no-touch saphenous vein is an excellent alternative conduit to the radial artery 8 years after coronary artery bypass grafting : A randomized trial

Dreifaldt, Mats, 1959- (författare)
Örebro universitet,Institutionen för medicinska vetenskaper,Region Örebro län,Department of Cardiothoracic and Vascular Surgery
Mannion, John D. (författare)
Department of Surgery, Bayhealth Medical Center, Dover, USA
Geijer, Håkan, 1961- (författare)
Örebro universitet,Institutionen för medicinska vetenskaper,Department of Radiology
visa fler...
Lidén, Mats, 1976- (författare)
Örebro universitet,Institutionen för medicinska vetenskaper,Region Örebro län,Department of Radiology
Bodin, Lennart (författare)
Karolinska Institutet
de Souza, Domingos Ramos, 1954- (författare)
Örebro universitet,Institutionen för medicinska vetenskaper,Region Örebro län,Department of Cardiothoracic and Vascular Surgery
visa färre...
 (creator_code:org_t)
Elsevier, 2021
2021
Engelska.
Ingår i: Journal of Thoracic and Cardiovascular Surgery. - : Elsevier. - 0022-5223 .- 1097-685X. ; 161:2, s. 624-630
  • Tidskriftsartikel (refereegranskat)
Abstract Ämnesord
Stäng  
  • Background: In 2004, a prospective randomized trial demonstrated that after 3 years, saphenous veins (SVs) harvested with a no touch (NT) technique had a greater patency than radial grafts for coronary bypass surgery. Here we report the 8-year follow-up data of this trial.Methods: The trial included 108 patients undergoing coronary artery bypass grafting (CABG). Each patient was assigned to receive 1 NT SV and 1 radial artery (RA) graft to either the left or right coronary territory to complement the left internal thoracic artery (LITA). Sequential grafting was common, so overall graft patency as well as the patency of each anastomosis were assessed.Results: Angiography was performed in 84 patients (78%) at mean of 97 months postoperatively. Graft patency were high and similar for both NT and RA: 86% for NT versus 79% for RA (P = .22). The patency of coronary anastomoses was significantly higher with the NT SV grafts (91% vs 81%; P = .046). The NT grafts also had excellent patency in coronary arteries with <90% stenosis (93% patency) and in coronary arteries of small diameter (87% patency) or with mild calcification (88% patency). Patency for the LITA was 92%.Conclusions: NT SV grafts have excellent patency similar to that of RA grafts after 8 years. In addition, NT SV grafts can be used in situations that are not ideal for RA grafts.

Ämnesord

MEDICIN OCH HÄLSOVETENSKAP  -- Klinisk medicin -- Kardiologi (hsv//swe)
MEDICAL AND HEALTH SCIENCES  -- Clinical Medicine -- Cardiac and Cardiovascular Systems (hsv//eng)

Nyckelord

CABG
saphenous vein
radial artery
no touch technique
patency

Publikations- och innehållstyp

ref (ämneskategori)
art (ämneskategori)

Hitta via bibliotek

Till lärosätets databas

Sök utanför SwePub

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Stäng

Kopiera och spara länken för att återkomma till aktuell vy