SwePub
Sök i LIBRIS databas

  Utökad sökning

WFRF:(Lidén Per)
 

Sökning: WFRF:(Lidén Per) > Quantitative T2* im...

Quantitative T2* imaging of iron overload in a non-dedicated center - Normal variation, repeatability and reader variation

Lidén, Mats, 1976- (författare)
Örebro universitet,Institutionen för medicinska vetenskaper,Region Örebro län,Department of Radiology
Adrian, David (författare)
Department of Radiology, Örebro University Hospital, Region Örebro County, Sweden
Widell, Jonas (författare)
Department of Radiology, Örebro University Hospital, Region Örebro County, Sweden
visa fler...
Uggla, Bertil, 1962- (författare)
Örebro universitet,Institutionen för medicinska vetenskaper,Department of Medicine
Thunberg, Per, 1968- (författare)
Örebro universitet,Institutionen för medicinska vetenskaper,Department of Medical Physics
visa färre...
 (creator_code:org_t)
Elsevier, 2021
2021
Engelska.
Ingår i: European journal of radiology open. - : Elsevier. - 2352-0477. ; 8
  • Tidskriftsartikel (refereegranskat)
Abstract Ämnesord
Stäng  
  • Background: Patients with transfusion dependent anemia are at risk of complications from iron overload. Quantitative T2* magnetic resonance imaging (MRI) is the best non-invasive method to assess iron deposition in the liver and heart and to guide chelation therapy.Purpose: To investigate the image quality and inter-observer variations in T2* measurements of the myocardium and the liver, and to obtain the lower limit of cardiac and hepatic quantitative T2* values in patients without suspicion of iron overload.Material and methods: Thirty-eight patients referred for cardiac MRI were prospectively included in the study. Three patients were referred with, and 35 without suspicion of iron overload. Quantitative T2* parametric maps were obtained on a 1.5 T MRI system in the cardiac short axis and liver axial view. Two readers independently assessed the image quality and the representative and the lowest T2* value in the myocardium and the liver.Results: The normal range of representative T2* values in the myocardium and liver was 24-45 ms and 14-37 ms, respectively. None of the 35 participants (0 %, 95 % confidence interval 0-11 %) in the normal reference group demonstrated representative T2* values below previously reported lower limits in the myocardium (20 ms) or the liver (8 ms). Focal myocardial areas with T2* values near the lower normal range, 19-20 ms, were seen in two patients. The readers generally reported good image quality.Conclusion: T2* imaging for assessing iron overload can be performed in a non-dedicated center with sufficient image quality.

Ämnesord

MEDICIN OCH HÄLSOVETENSKAP  -- Klinisk medicin -- Radiologi och bildbehandling (hsv//swe)
MEDICAL AND HEALTH SCIENCES  -- Clinical Medicine -- Radiology, Nuclear Medicine and Medical Imaging (hsv//eng)

Nyckelord

Heart
Iron overload
Liver
Quantitative MRI
T2 star
Thalassemia

Publikations- och innehållstyp

ref (ämneskategori)
art (ämneskategori)

Hitta via bibliotek

Till lärosätets databas

Sök utanför SwePub

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Stäng

Kopiera och spara länken för att återkomma till aktuell vy