SwePub
Sök i LIBRIS databas

  Utökad sökning

WFRF:(Ahlström Margareta)
 

Sökning: WFRF:(Ahlström Margareta) > Validity and reliab...

Validity and reliability of physical activity measures in multiple sclerosis

Anens, Elisabeth (författare)
Uppsala universitet,Åsenlöf: Fysioterapi
Ahlström, Isabell (författare)
Uppsala universitet,Åsenlöf: Fysioterapi
Emtner, Margareta (författare)
Uppsala universitet,Åsenlöf: Fysioterapi
visa fler...
Zetterberg, Lena, 1961- (författare)
Uppsala universitet,Åsenlöf: Fysioterapi
Nilsagård, Ylva, 1964- (författare)
Örebro universitet,Institutionen för hälsovetenskaper,Region Örebro län,Region Örebro County, University Research Health Care Centre, Örebro, Sweden
Hellström, Karin (författare)
Uppsala universitet,Åsenlöf: Fysioterapi
visa färre...
 (creator_code:org_t)
2021-11-05
2023
Engelska.
Ingår i: Physiotherapy Theory and Practice. - : Taylor & Francis. - 0959-3985 .- 1532-5040. ; 39:1, s. 137-153
  • Tidskriftsartikel (refereegranskat)
Abstract Ämnesord
Stäng  
  • PURPOSE: The purpose was to evaluate the psychometric properties of physical activity measures in persons with multiple sclerosis (PwMS).METHODS: Adults with multiple sclerosis were recruited, n = 30 (validation) and n = 57 (test-retest). Steps measured with PiezoRX, Yamax SW200 and ActiGraph GT9X Link (AGlink) and time in different positions measured with AGlink were validated against data from video analysis. Psychometric properties of the Physical Activity and Disability Survey - Revised Swedish version (PADS-R(Sw)) was evaluated.RESULTS: The most valid measures were AGlink using the low-frequency extension filter, and PiezoRX with median absolute percentage errors (MeAPEs) of 0.9-3.1% and 1.3-3.3%. The MeAPEs were higher for Yamax SW200 (2.9-21.0%), AGlink display (3.6-44.8%) and AGlink normal filter (8.9-48.9%), indicating low validity. AGlink was not valid in measurements of sitting (MeAPE 12.0-12.5%) or lying (MeAPE 31.0-41.7%). The correlation between PADS-R(Sw) and AGlink steps was r = 0.492 (p = .009). The relative reliability of PADS-R(Sw) was ICC2,1 0.85 (CI 0.76-0.91), and absolute reliability was SEM 0.54.CONCLUSION: AGlink and PiezoRX were valid measures of steps in PwMS. The questionnaire PADS-R(Sw) was valid, with high relative reliability, but its absolute reliability was unsatisfactory.

Ämnesord

MEDICIN OCH HÄLSOVETENSKAP  -- Hälsovetenskap -- Sjukgymnastik (hsv//swe)
MEDICAL AND HEALTH SCIENCES  -- Health Sciences -- Physiotherapy (hsv//eng)

Nyckelord

Exercise
multiple sclerosis
physical activity
reproducibility of results
validation studies

Publikations- och innehållstyp

ref (ämneskategori)
art (ämneskategori)

Hitta via bibliotek

Till lärosätets databas

Sök utanför SwePub

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Stäng

Kopiera och spara länken för att återkomma till aktuell vy