SwePub
Sök i LIBRIS databas

  Utökad sökning

WFRF:(Wennerberg Erik)
 

Sökning: WFRF:(Wennerberg Erik) > Bone apposition to ...

Bone apposition to laminin-1 coated implants : Histologic and 3D evaluation

Bougas, Kostas (författare)
Malmö högskola,Odontologiska fakulteten (OD)
Jimbo, Ryo (författare)
Malmö högskola,Odontologiska fakulteten (OD)
Vandeweghe, Stefan (författare)
Malmö högskola,Odontologiska fakulteten (OD)
visa fler...
Hayashi, Mariko (författare)
Malmö högskola,Odontologiska fakulteten (OD)
Bryington, Matthew S. (författare)
Malmö högskola,Odontologiska fakulteten (OD)
Kozai, Yusuke (författare)
Kanagawa Dental College, Japan
Schwartz-Filho, Humberto Osvaldo (författare)
Sao Paulo State University, Brazil
Tovar, Nick M. (författare)
New York University, USA
Adolfsson, Erik (författare)
RISE,IVF
Ono, Daisuke (författare)
Nagasaki University, Japan
Coelho, Paulo Guilherme (författare)
New York University, USA
Wennerberg, Ann (författare)
Malmö högskola,Odontologiska fakulteten (OD)
visa färre...
 (creator_code:org_t)
Elsevier BV, 2013
2013
Engelska.
Ingår i: International Journal of Oral and Maxillofacial Surgery. - : Elsevier BV. - 0901-5027 .- 1399-0020. ; 42:5, s. 677-682
  • Tidskriftsartikel (refereegranskat)
Abstract Ämnesord
Stäng  
  • Laminin-1 has been reported as one of the factors responsible for the nucleation of calcium phosphates and, in vitro, has been reported to selectively recruit osteoprogenitors. This article focused on its in vivo effects, and evaluated the effect of laminin-1 local application on osseointegration. Polished cylindrical hydroxyapatite implants were coated with laminin-1 (test) and the bone responses in the rabbit tibiae after 2 and 4 weeks were evaluated and compared to the non-coated implants (control). Before the samples were processed for histological sectioning, they were three-dimensionally analysed with micro computed tomography (μCT). Both evaluation methods were analysed with regards to bone area around the implant and bone to implant contact. From the histologic observation, new bone formation around the laminin-1 coated implant at 2 weeks seemed to have increased the amount of supporting bone around the implant, however, at 4 weeks, the two groups presented no notable differences. The two-dimensional and three-dimensional morphometric evaluation revealed that both histologic and three-dimensional analysis showed some tendency in favour of the test group implants, however there was no statistical significance between the test and control group results.

Ämnesord

TEKNIK OCH TEKNOLOGIER  -- Materialteknik (hsv//swe)
ENGINEERING AND TECHNOLOGY  -- Materials Engineering (hsv//eng)
MEDICIN OCH HÄLSOVETENSKAP  -- Klinisk medicin -- Odontologi (hsv//swe)
MEDICAL AND HEALTH SCIENCES  -- Clinical Medicine -- Dentistry (hsv//eng)

Nyckelord

animal experiments
bone implant interactions
laminin
micro CT

Publikations- och innehållstyp

ref (ämneskategori)
art (ämneskategori)

Hitta via bibliotek

Till lärosätets databas

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Stäng

Kopiera och spara länken för att återkomma till aktuell vy