SwePub
Sök i LIBRIS databas

  Utökad sökning

WFRF:(Langer Sarka)
 

Sökning: WFRF:(Langer Sarka) > Effect of energy re...

  • Földváry, VeronikaSlovak University of Technology, Slovakia,Slovak University of Technology Bratislava (författare)

Effect of energy renovation on indoor air quality in multifamily residential buildings in Slovakia

  • Artikel/kapitelEngelska2017

Förlag, utgivningsår, omfång ...

  • Elsevier BV,2017
  • printrdacarrier

Nummerbeteckningar

  • LIBRIS-ID:oai:DiVA.org:ri-30814
  • https://urn.kb.se/resolve?urn=urn:nbn:se:ri:diva-30814URI
  • https://doi.org/10.1016/j.buildenv.2017.06.009DOI
  • https://research.chalmers.se/publication/251633URI
  • https://urn.kb.se/resolve?urn=urn:nbn:se:ivl:diva-3734URI

Kompletterande språkuppgifter

  • Språk:engelska
  • Sammanfattning på:engelska

Ingår i deldatabas

Klassifikation

  • Ämneskategori:ref swepub-contenttype
  • Ämneskategori:art swepub-publicationtype

Anmärkningar

  • A-rapport, A2265
  • Buildings are responsible for a substantial portion of the global energy consumption. Most of the multifamily residential buildings built in the 20th century in Central and Eastern Europe do not satisfy the current requirements on energy efficiency. Nationwide measures taken to improve the energy efficiency of these buildings rarely consider their impact on the indoor air quality (IAQ). The objective of the present study was to evaluate the impact of simple energy renovation on IAQ, air exchange rates (AER) and occupant satisfaction in Slovak residential buildings. Three pairs of identical naturally ventilated multifamily residential buildings were examined. One building in each pair was newly renovated, the other was in its original condition. Temperature, relative humidity (RH) and the concentration of carbon dioxide (CO2) were measured in 94 apartments (57%) during one week in the winter. A questionnaire related to perceived air quality, sick building syndrome symptoms and airing habits was filled by the occupants. In a companion experiment, the IAQ was investigated in 20 apartments (50%) of a single residential building before and after its renovation. In this experiment, concentrations of nitrogen dioxide (NO2), formaldehyde and total and individual volatile organic compounds (VOC) were also measured. CO2 concentrations were significantly higher and AERs were lower in the renovated buildings. Formaldehyde concentrations increased after renovation and were positively correlated with CO2 and RH. Energy renovation was associated with lower occupant satisfaction with IAQ. Energy retrofitting efforts should be complemented with improved ventilation in order to avoid adverse effects on IAQ.

Ämnesord och genrebeteckningar

Biuppslag (personer, institutioner, konferenser, titlar ...)

  • Bekö, GabrielDTU Technical University of Denmark, Denmark,Danmarks Tekniske Universitet,Technical University of Denmark (författare)
  • Langer, Sarka,1960IVL Svenska Miljöinstitutet(Swepub:ivl)P010239 (författare)
  • Arrhenius, KarineSP Sveriges Tekniska Forskningsinstitut AB,RISE,Kemi och material(Swepub:ri)KarineAr@ri.se (författare)
  • Petráš, DusanSlovak University of Technology, Slovakia,Slovak University of Technology Bratislava (författare)
  • Slovak University of Technology, SlovakiaSlovak University of Technology Bratislava (creator_code:org_t)

Sammanhörande titlar

  • Ingår i:Building and Environment: Elsevier BV122, s. 363-3720360-13231873-684X

Internetlänk

Hitta via bibliotek

Till lärosätets databas

Sök utanför SwePub

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Stäng

Kopiera och spara länken för att återkomma till aktuell vy