SwePub
Sök i LIBRIS databas

  Utökad sökning

WFRF:(Silander Isak)
 

Sökning: WFRF:(Silander Isak) > Gas equilibration g...

Gas equilibration gas modulation refractometry for assessment of pressure with sub-ppm precision

Silander, Isak, 1980- (författare)
Umeå universitet,Institutionen för fysik,Umeå University, Sweden
Hausmaninger, Thomas, 1987- (författare)
Umeå universitet,Institutionen för fysik,National Metrology Institute VTT MIKES, Finland,Umeå University, Sweden; VTT, Finland
Forssén, Clayton (författare)
Umeå universitet,Institutionen för fysik,Umeå University, Sweden
visa fler...
Zelan, Martin (författare)
RISE,Mätteknik
Axner, Ove (författare)
Umeå universitet,Institutionen för fysik,Umeå University, Sweden
visa färre...
 (creator_code:org_t)
AVS Science and Technology Society, 2019
2019
Engelska.
Ingår i: Journal of Vacuum Science and Technology B. - : AVS Science and Technology Society. - 2166-2746 .- 2166-2754. ; 37:4
  • Tidskriftsartikel (refereegranskat)
Abstract Ämnesord
Stäng  
  • Gas modulation refractometry (GAMOR) is a methodology that, by performing repeated reference assessments with the measurement cavity being evacuated while the reference cavity is held at a constant pressure, can mitigate drifts in dual Fabry-Perot cavity based refractometry. A novel realization of GAMOR, referred to as gas equilibration GAMOR, that outperforms the original realization of GAMOR, here referred to as single cavity modulated GAMOR (SCM-GAMOR), is presented. In this, the reference measurements are carried out by equalizing the pressures in the two cavities, whereby the time it takes to reach adequate conditions for the reference measurements has been reduced. This implies that a larger fraction of the measurement cycle can be devoted to data acquisition, which reduces white noise and improves on its short-term characteristics. The presented realization also encompasses a new cavity design with improved temperature stabilization and assessment. This has contributed to improved long-term characteristics of the GAMOR methodology. The system was characterized with respect to a dead weight pressure balance. It was found that the system shows a significantly improved precision with respect to SCM-GAMOR for all integration times. For a pressure of 4303 Pa, it can provide a response for short integration times (up to 10 min) of 1.5 mPa (cycle)1/2, while for longer integration times (up to 18 h), it shows an integration time-independent Allan deviation of 1 mPa (corresponding to a precision, defined as twice the Allan deviation, of 0.5 ppm), exceeding the original SCM-GAMOR system by a factor of 2 and 8, respectively. When used for low pressures, it can provide a precision in the sub-mPa region; for the case with an evacuated measurement cavity, the system provided, for up to 40 measurement cycles (ca. 1.5 h), a white noise of 0.7 mPa (cycle)1/2, and a minimum Allan deviation of 0.15 mPa. It shows a purely linear response in the 2.8-10.1 kPa range. This implies that the system can be used for the transfer of calibration over large pressure ranges with exceptional low uncertainty. © 2019 Author(s).

Ämnesord

TEKNIK OCH TEKNOLOGIER  -- Elektroteknik och elektronik -- Annan elektroteknik och elektronik (hsv//swe)
ENGINEERING AND TECHNOLOGY  -- Electrical Engineering, Electronic Engineering, Information Engineering -- Other Electrical Engineering, Electronic Engineering, Information Engineering (hsv//eng)
NATURVETENSKAP  -- Fysik -- Atom- och molekylfysik och optik (hsv//swe)
NATURAL SCIENCES  -- Physical Sciences -- Atom and Molecular Physics and Optics (hsv//eng)

Nyckelord

Data acquisition
Fabry-Perot interferometers
Integration
Modulation
Allan deviation
Constant pressures
Fabry-Perot cavity
Integration time
Linear response
Pressure balance
Reference measurements
Temperature stabilization
White noise

Publikations- och innehållstyp

ref (ämneskategori)
art (ämneskategori)

Hitta via bibliotek

Till lärosätets databas

Sök utanför SwePub

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Stäng

Kopiera och spara länken för att återkomma till aktuell vy