SwePub
Sök i LIBRIS databas

  Utökad sökning

WFRF:(Langer Sarka)
 

Sökning: WFRF:(Langer Sarka) > Chemistry and indoo...

Chemistry and indoor air quality in a multi-storey wooden passive (low energy) building : Formation of peroxyacetyl nitrate

Fischer, Andreas (författare)
Gothenburg University,Göteborgs universitet,Institutionen för kemi och molekylärbiologi,Department of Chemistry and Molecular Biology,University of Gothenburg, Sweden
Langer, Sarka, 1960 (författare)
RISE,SP Kemi Material och Ytor,IVL Swedish Environmental Research Institute, Sweden
Ljungström, Evert, 1949 (författare)
Gothenburg University,Göteborgs universitet,Institutionen för kemi och molekylärbiologi,Department of Chemistry and Molecular Biology,University of Gothenburg, Sweden
 (creator_code:org_t)
SAGE Publications Ltd, 2014
2014
Engelska.
Ingår i: Indoor + Built Environment. - : SAGE Publications Ltd. - 1420-326X .- 1423-0070. ; 23:3, s. 485-496
  • Tidskriftsartikel (refereegranskat)
Abstract Ämnesord
Stäng  
  • Indoor air measurements were conducted in one unoccupied apartment of a 'near-zero-energy' residential building with a unique, wooden construction. Ozone, NO2, fine particles and volatile organic compounds, formaldehyde, acetaldehyde and peroxyacetyl nitrate (PAN) were measured under 'as is' conditions and after intentional intervention by adding ozone to simulate an ambient air ozone episode. Undisturbed concentrations were: O 3 5-10 ppb, NO2 5-8 ppb, fine particles 2000-5000 cm -3, formaldehyde 35 ± 5 μg/m3, PAN 0.3 ppb. During intervention, O3 was 50-60 ppb, NO2 15-20 ppb, fine particles 20,000-25,000 cm-3, formaldehyde 44 ± 2 μg/m3 and PAN 0.7-1 ppb. It was shown that chemical reactions had taken place in the indoor air. Ozone-initiated chemistry produced various aldehydes, PAN and, as a direct response to increased ozone concentrations, also fine particles. Calculations made by a simple model of PAN formation showed that an air change rate of around 0.2 h-1 would provide optimum conditions for PAN formation in a setting comparable to that of the investigated apartment. This air change rate is well below the Swedish national minimum of 0.5 h-1. Further, the calculations show that the non-photochemical PAN formation could be a consequence of mixing ozone and nitrogen dioxide with terpenes and acetaldehyde.

Ämnesord

NATURVETENSKAP  -- Kemi (hsv//swe)
NATURAL SCIENCES  -- Chemical Sciences (hsv//eng)
NATURVETENSKAP  -- Geovetenskap och miljövetenskap -- Miljövetenskap (hsv//swe)
NATURAL SCIENCES  -- Earth and Related Environmental Sciences -- Environmental Sciences (hsv//eng)

Nyckelord

Fine particles
Indoor air chemistry
Low-energy wooden building
Ozone
Peroxyacetyl nitrate
Terpenes
Ventilation
acetaldehyde
aldehyde derivative
formaldehyde
nitrogen dioxide
peroxyacetylnitrate
terpene derivative
volatile organic compound
air quality
ambient air
article
building
calculation
chemical reaction
chemistry
energy
priority journal
residential area
simulation
Indoor air chemistry
Low-energy wooden building
Ozone
Peroxyacetyl nitrate
Terpenes
Fine particles
Ventilation

Publikations- och innehållstyp

ref (ämneskategori)
art (ämneskategori)

Hitta via bibliotek

Till lärosätets databas

Sök utanför SwePub

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Stäng

Kopiera och spara länken för att återkomma till aktuell vy