Data center heated ...
Data center heated greenhouses, a matter for enhanced food self-sufficiency in sub-arctic regions
-
- Markeby Ljungqvist, Hampus (författare)
- Luleå tekniska universitet,Energivetenskap
-
- Mattsson, Louise (författare)
- RISE,Datavetenskap,Rise ICE Datacenter, 973 47, Luleå, Sweden
-
- Risberg, Mikael (författare)
- Luleå tekniska universitet,Energivetenskap
-
visa fler...
-
- Vesterlund, Mattias (författare)
- RISE,Datavetenskap,Rise ICE Datacenter, 973 47, Luleå, Sweden
-
visa färre...
-
(creator_code:org_t)
- Elsevier Ltd, 2021
- 2021
- Engelska.
-
Ingår i: Energy. - : Elsevier Ltd. - 0360-5442 .- 1873-6785. ; 215
- Relaterad länk:
-
https://doi.org/10.1...
-
visa fler...
-
https://doi.org/10.1...
-
https://urn.kb.se/re...
-
https://doi.org/10.1...
-
https://urn.kb.se/re...
-
visa färre...
Abstract
Ämnesord
Stäng
- This paper examines the possibility of increasing Northern Sweden's degree of self-sufficiency in food supply, at the 65th latitude, by using a data center as a heating source for greenhouse production. A dynamic building energy simulation software was used to compute both the hourly exhaust air output from a 1 MW data center for one year and the corresponding heating demand for two different greenhouse sizes, 2000 m2 and 10 000 m2, and two different production scenarios. Partial year production, 1 Mars – 15 October, without grow lights and full-year production with grow lights. The study showed that 5.5–30.5% of the electrical input to a 1 MW data center could be recovered. The 2000 m2 greenhouse could operate almost entirely, 89.7–97.9%, on excess heat while only 50.0–61.5% of the 10 000 m2 greenhouse heating demand could be met for full- and partial-year production, respectively. Furthermore, it is concluded that the 10 000 m2 greenhouse with full year production was the most prominent case and would cost-effectively yield 7.6% of northern Sweden's vegetable self-sufficiency.
Ämnesord
- TEKNIK OCH TEKNOLOGIER -- Maskinteknik -- Energiteknik (hsv//swe)
- ENGINEERING AND TECHNOLOGY -- Mechanical Engineering -- Energy Engineering (hsv//eng)
Nyckelord
- Data center
- Excess heat
- Greenhouse production
- Heat recovery
- Waste heat
- Computer software
- Food supply
- Greenhouses
- Building energy simulations
- Data centers
- Electrical inputs
- Greenhouse heating
- Heating demand
- Heating source
- Northern sweden
- Thermal processing (foods)
- arctic environment
- food consumption
- greenhouse gas
- self sufficiency
- simulation
- software
- vegetable
- Sweden
- Energiteknik