SwePub
Sök i LIBRIS databas

  Utökad sökning

WFRF:(Hanning Anne Charlotte)
 

Sökning: WFRF:(Hanning Anne Charlotte) > Development and val...

Development and validation of a method for the quantification of extractable perfluoroalkyl acids (PFAAs) and perfluorooctane sulfonamide (FOSA) in textiles

van der Veen, Ike (författare)
VU University, Netherlands
Weiss, Jana M. (författare)
VU University, Netherlands
Hanning, Anne-Charlotte (författare)
RISE,IVF
visa fler...
de Boer, Jacob (författare)
VU University, Netherlands
Leonards, Pim E.G. (författare)
VU University, Netherlands
visa färre...
 (creator_code:org_t)
Elsevier BV, 2016
2016
Engelska.
Ingår i: Talanta. - : Elsevier BV. - 0039-9140 .- 1873-3573. ; 147, s. 8-15
  • Tidskriftsartikel (refereegranskat)
Abstract Ämnesord
Stäng  
  • In textiles, like outdoor clothing, per- and polyfluoroalkyl substances (PFASs) are often used for durable water repellency (DWR) of the final products. The analytical performance to determine the concentration of these chemicals available for exposure to humans and to the environment need to be established. Here a method for the extraction and analysis of one class of PFASs, namely perfluoroalkyl acids (PFAAs), in outdoor clothing was developed and validated. The PFAAs which were validated, included perfluoroalkyl carboxylic acids (PFCAs) (C4-C14), and perfluoroalkane sulfonic acids (PFSAs) (C4, C6, C7, C8). In addition, perfluorooctane sulfonamide (FOSA) was included in this study. The method was based on an organic solvent extraction and analysis by high-performance liquid chromatography-tandem mass spectrometry (LC-MS/MS). No further cleaning was needed. Two commonly used organic solvent compositions were evaluated for the optimal extraction, i.e. methanol and acetone/acetonitrile (80:20, v/v), and the number and duration of the sequential extractions were optimized. Results showed that two sequential extractions with 5 mL methanol and an extraction time of 30 min gave an optimal performance with an extraction efficiency of >90%. The influence of matrix on the quantification of PFAAs was studied. This indicated ion suppression due to different matrix effects or sorption behavior to specific textile samples. Validation of the entire method showed overall recoveries of>80% and relative standard deviations (RSDs) of<9% (n=3) for repeatability and <20% (n=3) for reproducibility. This is the first validation of an analytical method for the analysis of extractable PFCAs, PFSAs and FOSA associated to textiles, which is of high importance due to the regulation of PFAAs in textile.

Ämnesord

TEKNIK OCH TEKNOLOGIER  -- Materialteknik (hsv//swe)
ENGINEERING AND TECHNOLOGY  -- Materials Engineering (hsv//eng)

Nyckelord

Method development
Perfluoroalkane sulfonic acids
Perfluoroalkyl acids
Perfluoroalkyl carboxylic acids
Perfluorooctane sulfonamide
Textile

Publikations- och innehållstyp

ref (ämneskategori)
art (ämneskategori)

Hitta via bibliotek

  • Talanta (Sök värdpublikationen i LIBRIS)

Till lärosätets databas

Hitta mer i SwePub

Av författaren/redakt...
van der Veen, Ik ...
Weiss, Jana M.
Hanning, Anne-Ch ...
de Boer, Jacob
Leonards, Pim E. ...
Om ämnet
TEKNIK OCH TEKNOLOGIER
TEKNIK OCH TEKNO ...
och Materialteknik
Artiklar i publikationen
Talanta
Av lärosätet
RISE

Sök utanför SwePub

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Stäng

Kopiera och spara länken för att återkomma till aktuell vy