SwePub
Sök i LIBRIS databas

  Utökad sökning

onr:"swepub:oai:DiVA.org:ri-61234"
 

Sökning: onr:"swepub:oai:DiVA.org:ri-61234" > Experimental invest...

  • Gernay, ThomasJohns Hopkins University, USA (författare)

Experimental investigation of structural failure during the cooling phase of a fire : Timber columns

  • Artikel/kapitelEngelska2023

Förlag, utgivningsår, omfång ...

  • 2022-10-22
  • John Wiley and Sons Ltd,2023
  • printrdacarrier

Nummerbeteckningar

  • LIBRIS-ID:oai:DiVA.org:ri-61234
  • https://urn.kb.se/resolve?urn=urn:nbn:se:ri:diva-61234URI
  • https://doi.org/10.1002/fam.3110DOI

Kompletterande språkuppgifter

  • Språk:engelska
  • Sammanfattning på:engelska

Ingår i deldatabas

Klassifikation

  • Ämneskategori:ref swepub-contenttype
  • Ämneskategori:art swepub-publicationtype

Anmärkningar

  •  Funding details: Johns Hopkins University, JHU; Funding details: Technische Universität Braunschweig; Funding details: Politecnico di Milano; Funding text 1: The support from the project partners is gratefully acknowledged: Johns Hopkins University through the startup grant for Dr. Gernay; the Institute of Building Materials, Concrete Construction and Fire Safety of Technische Universität Braunschweig, Division of Fire Safety; CERIB, Fire Testing Centre; Liege University; RISE Research Institutes of Sweden; and Politecnico di Milano.
  • This paper describes fire tests on loaded glued laminated timber columns in which the structural response was measured during the heating and cooling phases. Identical columns with 280 × 280 mm2 cross-section and 3.7 m length were tested under various heating durations in a standard furnace to investigate integrity to full burnout. Two of the columns were subjected to ISO 834 heating until failure and their measured fire resistance was 55 and 58 min, respectively. Two columns were subjected to 15 min of ISO 834 heating followed by controlled cooling; these columns failed during the cooling phase, respectively after 98 and 153 min. Flame self-extinction occurred after approximately 40 min while smoldering continued locally. Two columns tested under 10 min of ISO 834 heating both survived the defined heating–cooling exposure. Thermocouples inside the columns show sustained temperature increases for hours after the end of the heating phase. These full-scale furnace experiments show that timber columns may fail during the cooling phase after exposure to standard heating for about 25% of the standard fire resistance duration. These results, in line with previous numerical predictions, highlight the need for further investigation into fire safety until full burnout for timber structures. 

Ämnesord och genrebeteckningar

Biuppslag (personer, institutioner, konferenser, titlar ...)

  • Zehfuß, JochenTechnische Universität Braunschweig, Germany (författare)
  • Brunkhorst, SvenTechnische Universität Braunschweig, Germany (författare)
  • Robert, FabienneCERIB Fire Testing Centre, France (författare)
  • Bamonte, PatrickPolitecnico di Milano, Italy (författare)
  • McNamee, RobertRISE,Brand och Säkerhet,Lund University, Sweden(Swepub:ri)RobertJ@ri.se (författare)
  • Mohaine, SiyimaneCERIB Fire Testing Centre, France (författare)
  • Franssen, Jean-MarcLiege University, Belgium (författare)
  • Johns Hopkins University, USATechnische Universität Braunschweig, Germany (creator_code:org_t)

Sammanhörande titlar

  • Ingår i:Fire and Materials: John Wiley and Sons Ltd47:4, s. 445-0308-05011099-1018

Internetlänk

Hitta via bibliotek

Till lärosätets databas

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Stäng

Kopiera och spara länken för att återkomma till aktuell vy