Calibration of insulin pumps based on discrete doses at given cycle times

Bissig, Hugo (författare)
METAS Federal Institute of Metrology, Switzerland
Büker, Oliver (författare)
RISE,Mätteknik
Stolt, Krister (författare)
RISE,Mätteknik
visa fler...
Batista, Elsa (författare)
IPQ Metrology Department, Portugal
Afonso, Joana (författare)
NOVA School of Science and Technology, Portugal
Zagnoni, Michele (författare)
University of Strathclyde, UK
Vroman, Rozan (författare)
University of Strathclyde, UK
Kjeldsen, Henrik (författare)
DTI Danish Technological Institute, Denmark
Niemann, Anders (författare)
DTI Danish Technological Institute, Denmark
Schroeter, Joerk (författare)
Technische Hochschule Lübeck, germany
visa färre...
 (creator_code:org_t)
2022-09-27
2023
Engelska.
Ingår i: Biomedizinische Technik (Berlin. Zeitschrift). - : De Gruyter Open Ltd. - 1862-278X .- 0013-5585. ; 68:1, s. 67-77
  • Tidskriftsartikel (refereegranskat)
Abstract Ämnesord
Stäng  
  • One application in the medical treatment at very small flow rates is the usage of an Insulin pump that delivers doses of insulin at constant cycle times for a specific basal rate as quasi-continuous insulin delivery, which is an important cornerstone in diabetes management. The calibration of these basal rates are performed by either gravimetric or optical methods, which have been developed within the European Metrology Program for Innovation and Research (EMPIR) Joint Research Project (JRP) 18HLT08 Metrology for drug delivery II (MeDDII). These measurement techniques are described in this paper, and an improved approach of the analytical procedure given in the standard IEC 60601-2-24:2012 for determining the discrete doses and the corresponding basal rates is discussed in detail. These improvements allow detailed follow up of dose cycle time and delivered doses as a function of time to identify some artefacts of the measurement method or malfunctioning of the insulin pump. Moreover, the calibration results of different basal rates and bolus deliveries for the gravimetric and the optical methods are also presented. Some analysis issues that should be addressed to prevent misinterpreting of the calibration results are discussed. One of the main issues is the average over a period of time which is an integer multiple of the cycle time to determine the basal rate with the analytical methods described in this paper. 

Ämnesord

MEDICIN OCH HÄLSOVETENSKAP  -- Klinisk medicin (hsv//swe)
MEDICAL AND HEALTH SCIENCES  -- Clinical Medicine (hsv//eng)

Nyckelord

calibration
dose accuracy
insulin pump
traceability
Controlled drug delivery
Insulin
Pumps
Targeted drug delivery
Cycle time
Diabetes management
Insulin delivery
Insulin pumps
Medical treatment
Optical methods
Pump-based
Small flow-rate

Publikations- och innehållstyp

ref (ämneskategori)
art (ämneskategori)

Hitta via bibliotek

Till lärosätets databas

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Stäng

Kopiera och spara länken för att återkomma till aktuell vy