SwePub
Sök i LIBRIS databas

  Utökad sökning

WFRF:(Wickman M.)
 

Sökning: WFRF:(Wickman M.) > (1994) > Reduced mite allerg...

Reduced mite allergen levels in dwellings with mechanical exhaust and supply ventilation.

Wickman, M (författare)
Department of Environmental Health and infectious Diseases Control, Karolinska Hospital, Stockholm
Emenius, G (författare)
Department of Environmental Health and infectious Diseases Control, Karolinska Hospital, Stockholm
Egmar, Ann-Charlotte (författare)
Department of Environmental Health and infectious Diseases Control, Karolinska Hospital, Stockholm
visa fler...
Axelsson, G (författare)
Department of Environmental Health and infectious Diseases Control, Karolinska Hospital, Stockholm
Pershagen, G (författare)
Department of Environmental Health and infectious Diseases Control, Karolinska Hospital, Stockholm
visa färre...
 (creator_code:org_t)
Blackwell Publishing, 1994
1994
Engelska.
Ingår i: Clinical and Experimental Allergy. - : Blackwell Publishing. - 0954-7894 .- 1365-2222. ; 24:2, s. 109-114
  • Tidskriftsartikel (refereegranskat)
Abstract Ämnesord
Stäng  
  • Seventy similar bungalows constructed between 1968 and 1970 in the same suburban area of Stockholm were investigated regarding the content of house dust mite allergen, absolute indoor humidity, type of ventilation and basement construction. Houses with mechanical exhaust and supply ventilation had an indoor humidity above 7 g/kg less often than houses without this type of ventilation (Odds ratio 0.1, 95% confidence interval 0.0-0.2). Furthermore, only five of the 24 houses with exhaust and supply ventilation contained mattress dust mite allergen concentrations exceeding the median value (98.5 ng/g) compared with 30 of 46 hours which did not have such ventilation (odds ratio = 0.1, C.I. 0.0-0.5). Houses with both natural ventilation and crawl space basement harboured significantly less mattress mite allergen than houses having the same type of ventilation, but with a concrete slab basement. In a cold temperature climate, type of building construction and ventilation seem to be important for the occurrence of house dust mite allergens in dwellings. Our results indicate that modern energy-efficient houses should be equipped with mechanical exhaust and supply ventilation to reduce indoor air humidity during the dry winter months and the risk of mite infestation.

Nyckelord

allergen
ventilation

Publikations- och innehållstyp

ref (ämneskategori)
art (ämneskategori)

Hitta via bibliotek

Till lärosätets databas

Sök utanför SwePub

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Stäng

Kopiera och spara länken för att återkomma till aktuell vy