SwePub
Sök i LIBRIS databas

  Extended search

WFRF:(Lundin Lennart)
 

Search: WFRF:(Lundin Lennart) > Evaluating vacuum p...

Evaluating vacuum phototriodes designed for the PANDA electromagnetic calorimeter

Makonyi, Karoly (author)
Stockholms universitet,Fysikum
Marcks von Würtemberg, Klas (author)
Stockholms universitet,Fysikum
Tegnér, Per-Erik (author)
Stockholms universitet,Fysikum
show more...
Hansen, Kurt (author)
Lund University,Lunds universitet,MAX IV-laboratoriet,MAX IV Laboratory
Isaksson, Lennart (author)
Lund University,Lunds universitet,MAX IV-laboratoriet,MAX IV Laboratory
Lundin, Magnus (author)
Lund University,Lunds universitet,MAX IV-laboratoriet,MAX IV Laboratory
Schröder, Bent (author)
Lund University,Lunds universitet,MAX IV-laboratoriet,MAX IV Laboratory
Balkeståhl, Li (author)
Uppsala universitet,Kärnfysik
Fransson, Kjell (author)
Uppsala universitet,Kärnfysik
Johansson, Tord (author)
Uppsala universitet,Kärnfysik
Rosenbaum, C. (author)
Uppsala universitet,Institutionen för fysik och astronomi
Wolke, Magnus (author)
Uppsala universitet,Kärnfysik
Erni, W. (author)
Keshelashvili, I. (author)
Krushe, B. (author)
show less...
 (creator_code:org_t)
Elsevier BV, 2014
2014
English.
In: Nuclear Instruments and Methods in Physics Research Section A. - : Elsevier BV. - 0168-9002 .- 1872-9576 .- 0167-5087. ; 763, s. 36-43
  • Journal article (peer-reviewed)
Abstract Subject headings
Close  
  • In this work properties of a vacuum phototriode (VPT) and preamplifier unit designed for the electromagnetic calorimeter of the PANDA experiment being built at FAIR are investigated. With the use of lead tungstate and lanthanium bromide scintillators the VPT properties are studied at low photon energies, from tens of key in the lanthanium bromide measurements and between 10 MeV and 60 MeV in the lead tungstate measurements. At these energies the noise of the VPT unit can be expected to influence its performance significantly. It is shown that the noise contribution to the measured energy resolution, under optimal conditions, is consistent with a fluctuation of (one standard deviation) approximately 200 electrons at the VPT anode. For a lead tungstate crystal this is equivalent to a noise of 1.2 MeV. For lanthanium bromide this makes it possible to use VPTs for gamma ray spectroscopy above a few hundreds of keV without noticeable effects on the energy resolution compared to measurements with a standard photomultiplier.

Subject headings

NATURVETENSKAP  -- Fysik (hsv//swe)
NATURAL SCIENCES  -- Physical Sciences (hsv//eng)
NATURVETENSKAP  -- Fysik -- Acceleratorfysik och instrumentering (hsv//swe)
NATURAL SCIENCES  -- Physical Sciences -- Accelerator Physics and Instrumentation (hsv//eng)

Keyword

Vacuum phototriodes
Lead tungstate
Electromagnetic calorimeter
PANDA
Tagged photons
Lanthanium bromide
Vacuum phototriodes
Lead tungstate
Electromagnetic calorimeter
PANDA
Tagged photons
Lanthanium bromide

Publication and Content Type

ref (subject category)
art (subject category)

Find in a library

To the university's database

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Close

Copy and save the link in order to return to this view