Calibration of hydrogen Coriolis flow meters using nitrogen and air and investigation of the influence of temperature on measurement accuracy

MacDonald, M. (författare)
NEL, UK
de Huu, M. (författare)
METAS, Switzerland
Maury, R. (författare)
CESAME-EXADEBIT SA, France
visa fler...
Büker, Oliver (författare)
RISE,Mätteknik
visa färre...
 (creator_code:org_t)
Elsevier Ltd, 2021
2021
Engelska.
Ingår i: Flow Measurement and Instrumentation. - : Elsevier Ltd. - 0955-5986 .- 1873-6998. ; 79
  • Tidskriftsartikel (refereegranskat)
Abstract Ämnesord
Stäng  
  • The performance of four Coriolis flow meters designed for use in hydrogen refuelling stations was evaluated with air and nitrogen by three members of the MetroHyVe JRP consortium; NEL, METAS and CESAME EXADEBIT. A wide range of conditions were tested overall, with gas flow rates ranging from (0.05–2) kg/min and pressures ranging from (20–86) bar. The majority of tests were conducted at nominal pressures of either 20 bar or 40 bar, in order to match the density of hydrogen at 350 bar and 20 °C or 700 bar and −40 °C. For the conditions tested, pressure did not have a noticeable influence on meter performance. When the flow meters were operated at ambient temperatures and within the manufacturer's recommended flow rate ranges, errors were generally within ±1%. Errors within ±0.5% were achievable for the medium to high flow rates. The influence of temperature on meter performance was also studied, with testing under both stable and transient conditions and temperatures as low as −40 °C. When the tested flow meters were allowed sufficient time to reach thermal equilibrium with the incoming gas, temperature effects were limited. The magnitude and spread of errors increased, but errors within ±2% were achievable at moderate to high flow rates. Conversely, errors as high as 15% were observed in tests where logging began before temperatures stabilised and there was a large difference in temperature between the flow meter and the incoming gas. One of the flow meters tested with nitrogen was later installed in a hydrogen refuelling station and tested against the METAS Hydrogen Field Test Standard (HFTS). Under these conditions, errors ranged from 0.47% to 0.91%. Testing with nitrogen at the same flow rates yielded errors of −0.61% to −0.82%. © 2021 The Authors

Ämnesord

TEKNIK OCH TEKNOLOGIER  -- Elektroteknik och elektronik -- Annan elektroteknik och elektronik (hsv//swe)
ENGINEERING AND TECHNOLOGY  -- Electrical Engineering, Electronic Engineering, Information Engineering -- Other Electrical Engineering, Electronic Engineering, Information Engineering (hsv//eng)

Nyckelord

Coriolis
Flow meter
Hydrogen
Refuelling station
Air refueling
Errors
Flow measurement
Flow of gases
Flow rate
Low temperature testing
Nitrogen
Temperature
Coriolis flowmeters
Field test
High-flow rate
Hydrogen refuelling stations
Measurement accuracy
Nominal pressures
Thermal equilibriums
Transient conditions
Flowmeters

Publikations- och innehållstyp

ref (ämneskategori)
art (ämneskategori)

Hitta via bibliotek

Till lärosätets databas

Hitta mer i SwePub

Av författaren/redakt...
MacDonald, M.
de Huu, M.
Maury, R.
Büker, Oliver
Om ämnet
TEKNIK OCH TEKNOLOGIER
TEKNIK OCH TEKNO ...
och Elektroteknik oc ...
och Annan elektrotek ...
Artiklar i publikationen
Flow Measurement ...
Av lärosätet
RISE

Sök utanför SwePub

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Stäng

Kopiera och spara länken för att återkomma till aktuell vy