SwePub
Sök i LIBRIS databas

  Utökad sökning

db:Swepub
 

Sökning: db:Swepub > (2010-2025) > Laser capture micro...

Laser capture microdissection (LCM) and whole genome amplification (WGA) of DNA from normal breast tissue - optimization for genome wide array analyses.

Aaltonen, Kristina (författare)
Lund University,Lunds universitet,Bröstcancer-genetik,Sektion I,Institutionen för kliniska vetenskaper, Lund,Medicinska fakulteten,Breastcancer-genetics,Section I,Department of Clinical Sciences, Lund,Faculty of Medicine
Ebbesson, Anna (författare)
Lund University,Lunds universitet,Bröstcancer-genetik,Sektion I,Institutionen för kliniska vetenskaper, Lund,Medicinska fakulteten,Breastcancer-genetics,Section I,Department of Clinical Sciences, Lund,Faculty of Medicine
Wigerup, Caroline (författare)
Lund University,Lunds universitet,Bröstcancer-genetik,Sektion I,Institutionen för kliniska vetenskaper, Lund,Medicinska fakulteten,Breastcancer-genetics,Section I,Department of Clinical Sciences, Lund,Faculty of Medicine
visa fler...
Hedenfalk, Ingrid (författare)
Lund University,Lunds universitet,Bröstcancer-genetik,Sektion I,Institutionen för kliniska vetenskaper, Lund,Medicinska fakulteten,Breastcancer-genetics,Section I,Department of Clinical Sciences, Lund,Faculty of Medicine
visa färre...
 (creator_code:org_t)
2011-03-18
2011
Engelska.
Ingår i: BMC Research Notes. - : Springer Science and Business Media LLC. - 1756-0500. ; 4, s. 69-69
  • Tidskriftsartikel (refereegranskat)
Abstract Ämnesord
Stäng  
  • Background Laser capture microdissection (LCM) can be applied to tissues where cells of interest are distinguishable from surrounding cell populations. Here, we have optimized LCM for fresh frozen normal breast tissue where large amounts of fat can cause problems during microdissection. Since the amount of DNA needed for genome wide analyses, such as single nucleotide polymorphism (SNP) arrays, is often greater than what can be obtained from the dissected tissue, we have compared three different whole genome amplification (WGA) kits for amplification of DNA from LCM material. In addition, the genome wide profiling methods commonly used today require extremely high DNA quality compared to PCR based techniques and DNA quality is thus critical for successful downstream analyses. Findings We found that by using FrameSlides without glass backing for LCM and treating the slides with acetone after staining, the problems caused by excessive fat could be significantly decreased. The amount of DNA obtained after extraction from LCM tissue was not sufficient for direct SNP array analysis in our material. However, the two WGA kits based on Phi29 polymerase technology (Repli-g® (Qiagen) and GenomiPhi (GE Healthcare)) gave relatively long amplification products, and amplified DNA from Repli-g® gave call rates in the subsequent SNP analysis close to those from non-amplified DNA. Furthermore, the quality of the input DNA for WGA was found to be essential for successful SNP array results and initial DNA fragmentation problems could be reduced by switching from a regular halogen lamp to a VIS-LED lamp during LCM. Conclusions LCM must be optimized to work satisfactorily in difficult tissues. We describe a work flow for fresh frozen normal breast tissue where fat is inclined to cause problems if sample treatment is not adapted to this tissue. We also show that the Phi29-based Repli-g® WGA kit (Qiagen) is a feasible approach to amplify DNA of high quality prior to genome wide analyses such as SNP profiling.

Ämnesord

MEDICIN OCH HÄLSOVETENSKAP  -- Klinisk medicin -- Cancer och onkologi (hsv//swe)
MEDICAL AND HEALTH SCIENCES  -- Clinical Medicine -- Cancer and Oncology (hsv//eng)

Publikations- och innehållstyp

art (ämneskategori)
ref (ämneskategori)

Hitta via bibliotek

Till lärosätets databas

Sök utanför SwePub

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Stäng

Kopiera och spara länken för att återkomma till aktuell vy