Sökning: id:"swepub:oai:DiVA.org:su-135000" >
Molecularly imprint...
-
El-Beqqali, Aziza,1966-Stockholms universitet,Institutionen för miljövetenskap och analytisk kemi
(författare)
Molecularly imprinted polymer-sol-gel tablet toward micro-solid phase extraction : I. Determination of methadone in human plasma utilizing liquid chromatography-tandem mass spectrometry
- Artikel/kapitelEngelska2016
Förlag, utgivningsår, omfång ...
-
Elsevier BV,2016
-
printrdacarrier
Nummerbeteckningar
-
LIBRIS-ID:oai:DiVA.org:su-135000
-
https://urn.kb.se/resolve?urn=urn:nbn:se:su:diva-135000URI
-
https://doi.org/10.1016/j.aca.2016.07.001DOI
Kompletterande språkuppgifter
-
Språk:engelska
-
Sammanfattning på:engelska
Ingår i deldatabas
Klassifikation
-
Ämneskategori:ref swepub-contenttype
-
Ämneskategori:art swepub-publicationtype
Anmärkningar
-
In the present work molecularly imprinted sol-gel tablet (MIP-Tablet) was prepared. The MIP-sol-gel was prepared as a thin layer on polyethylene material in a tablet form. Methadone-d9 was selected as the template and 3-(propylmethacrylate)-trimethoxysilane was used as precursor. MIP-Tablet was applied for micro-solid phase extraction (μ-SPE). The MIP-Tablet was used for the determination of methadone in human plasma samples utilizing liquid chromatography-tandem mass spectrometry; and each tablet could be used twenty times. The extraction time was 10 min while desorption time was 6 min. Factors affecting the extraction efficiency such as desorption solvents, sample pH, salt addition, extraction time, desorption time and adsorption capacity were investigated. The calibration curves were obtained within the range of 5-5000 ng/mL using methadone in human plasma samples. The coefficients of determination (r(2)) values were >= 0.999 for all runs and the extraction recovery was >80%. The accuracy values for quality control samples varied from +3.6 to +9.7% and the inter-day precision (RSD %) values were ranged from 5.0 to 8.0%. The limit of detection was 1.0 ng/mL and the lower limit of quantification was 5 ng/mL utilizing methadone in human plasma samples.
Ämnesord och genrebeteckningar
Biuppslag (personer, institutioner, konferenser, titlar ...)
-
Abdel-Rehim, MohamedStockholms universitet,Institutionen för miljövetenskap och analytisk kemi(Swepub:su)rabde
(författare)
-
Stockholms universitetInstitutionen för miljövetenskap och analytisk kemi
(creator_code:org_t)
Sammanhörande titlar
-
Ingår i:Analytica Chimica Acta: Elsevier BV936, s. 116-1220003-26701873-4324
Internetlänk
Hitta via bibliotek
Till lärosätets databas