SwePub
Sök i LIBRIS databas

  Utökad sökning

WFRF:(Song Fei)
 

Sökning: WFRF:(Song Fei) > Dynamics of slow el...

Dynamics of slow electrons transmitting through straight glass capillary and tapered glass capillary

Wan, Cheng-Liang (författare)
Li, Peng-Fei (författare)
Qian, Li-Bing (författare)
visa fler...
Jin, Bo (författare)
Song, Guang-Yin (författare)
Gao, Zhi-Min (författare)
Zhou, Li-Hua (författare)
Zhang, Qi (författare)
Song, Zhang-Yong (författare)
Yang, Zhi-Hu (författare)
Shao, Jian-Xiong (författare)
Cui, Ying (författare)
Schuch, Reinhold (författare)
Stockholms universitet,Fysikum
Zhang, Hong-Qiang (författare)
Chen, Xi-Meng (författare)
visa färre...
 (creator_code:org_t)
Acta Physica Sinica, Chinese Physical Society and Institute of Physics, Chinese Academy of Sciences, 2016
2016
Kinesiska.
Ingår i: Wuli xuebao. - : Acta Physica Sinica, Chinese Physical Society and Institute of Physics, Chinese Academy of Sciences. - 1000-3290. ; 65:20
  • Tidskriftsartikel (refereegranskat)
Abstract Ämnesord
Stäng  
  • It has been found that the transmission rate of the electrons through insulating capillaries as a function of time/incident charge is not the same as that of the ions. The question arises that by using the electrons, if the negative charge patches can be formed to facilitate the transmission of the following electrons, thereby substantiating that the so-called guiding effect works also for electrons. This study aims to observe the time evolutions of the transmission of electrons through a straight glass tube and a tapered glass capillary. This will reveal the details of how and (or) if the negative charge patches can be formed when the electrons transport through them. In this work, a set of MCP/phosphor two-dimensional detection system based on Labview platform is developed to obtain the time evolution of the angular distribution of the transmitted electrons. The pulsed electron beams are obtained to test our detection system. The time evolution of the angular profile of 1.5 keV electrons transmitting through the glass tube/capillary is observed. The transmitted electrons are observed on the detector for a very short time and disappear for a time and then appear again for both the glass tube and tapered glass capillary, leading to an oscillation. The positive charge patches are formed in the insulating glass tube and tapered glass capillary since the secondary electron emission coefficient for the incident energy is larger than 1. It is due to the fact that fast discharge of the deposited charge leads to the increase of the transmission rate, while the fast blocking of the incident electrons due to the deposited positive charge leads to the decrease of the transmission rate. The geometrical configuration of the taper glass capillary tends to make the secondary electrons deposited at the exit part to form the negative patches that facilitate the transmission of electrons. This suggests that if the stable transmission needs to be reached for producing the electron micro-beam by using tapered glass capillaries, the steps must be taken to have the proper grounding and shielding of the glass capillaries and tubes. Our results show a difference in transmission through the insulating capillary between electrons and highly charged ions.

Ämnesord

NATURVETENSKAP  -- Fysik (hsv//swe)
NATURAL SCIENCES  -- Physical Sciences (hsv//eng)

Nyckelord

low energy electron
the full angular distribution of the transmitted electrons
glass capillaries
highly charged ions

Publikations- och innehållstyp

ref (ämneskategori)
art (ämneskategori)

Hitta via bibliotek

Till lärosätets databas

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Stäng

Kopiera och spara länken för att återkomma till aktuell vy