SwePub
Sök i LIBRIS databas

  Utökad sökning

onr:"swepub:oai:DiVA.org:su-139738"
 

Sökning: onr:"swepub:oai:DiVA.org:su-139738" > Dosimetric Comparis...

Dosimetric Comparison of Plans for Photon- or Proton-Beam Based Radiosurgery of Liver Metastases

Mondlane, Gracinda, 1987- (författare)
Stockholms universitet,Fysikum,Universidade Eduardo Mondlane, Mozambique
Gubanski, Michael (författare)
Karolinska Institutet
Lind, Pehr A. (författare)
Karolinska Institutet
visa fler...
Henry, Thomas (författare)
Stockholms universitet,Fysikum
Ureba, Ana (författare)
Karolinska Institutet,Stockholms universitet,Fysikum
Siegbahn, Albert (författare)
Karolinska Institutet,Stockholms universitet,Fysikum
visa färre...
 (creator_code:org_t)
2016
2016
Engelska.
Ingår i: International Journal of Particle Therapy. - 2331-5180. ; 3:2, s. 277-284
  • Tidskriftsartikel (refereegranskat)
Abstract Ämnesord
Stäng  
  • Purpose: Radiosurgery treatment of liver metastases with photon beams has been an established method for more than a decade. One method commonly used is the stereotactic body radiation therapy (SBRT) technique. The aim of this study was to investigate the potential sparing of the organs at risk (OARs) that the use of intensity-modulated proton therapy (IMPT), instead of SBRT, could enable.Patients and Methods: A comparative treatment-planning study of photon-beam and proton-beam based liver-cancer radiosurgery was performed. Ten patients diagnosed with liver metastasis and previously treated with SBRT at the Karolinska University Hospital were included in the study. New IMPT plans were prepared for all patients, while the original plans were set as reference plans. The IMPT planning was performed with the objective of achieving the same target dose coverage as with the SBRT plans. Pairwise dosimetric comparisons of the treatment plans were then performed for the OARs. A 2-sided Wilcoxon signed-rank test with significance level of 5% was carried out.Results: Improved sparing of the OARs was made possible with the IMPT plans. There was a significant decrease of the mean doses delivered to the following risk organs: the nontargeted part of the liver (P = .002), the esophagus (P = .002), the right kidney (P = .008), the spinal cord (P = .004), and the lungs (P = .002). The volume of the liver receiving less than 15 Gy was significantly increased with the IMPT plans (P = .004).Conclusion: The IMPT-based radiosurgery plans provided similar target coverage and significant dose reductions for the OARs compared with the photon-beam based SBRT plans. Further studies including detailed information about varying tissue heterogeneities in the beam path, due to organ motion, are required to evaluate more accurately whether IMPT is preferable for the radiosurgical treatment of liver metastases.

Ämnesord

NATURVETENSKAP  -- Fysik (hsv//swe)
NATURAL SCIENCES  -- Physical Sciences (hsv//eng)
MEDICIN OCH HÄLSOVETENSKAP  -- Klinisk medicin -- Cancer och onkologi (hsv//swe)
MEDICAL AND HEALTH SCIENCES  -- Clinical Medicine -- Cancer and Oncology (hsv//eng)
MEDICIN OCH HÄLSOVETENSKAP  -- Klinisk medicin -- Kirurgi (hsv//swe)
MEDICAL AND HEALTH SCIENCES  -- Clinical Medicine -- Surgery (hsv//eng)

Nyckelord

liver metastases
treatment planning
stereotactic body radiation therapy
intensity-modulated proton therapy
Medical Radiation Physics
medicinsk strålningsfysik

Publikations- och innehållstyp

ref (ämneskategori)
art (ämneskategori)

Hitta via bibliotek

Till lärosätets databas

Sök utanför SwePub

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Stäng

Kopiera och spara länken för att återkomma till aktuell vy