SwePub
Sök i LIBRIS databas

  Utökad sökning

WFRF:(de Wit Cynthia A.)
 

Sökning: WFRF:(de Wit Cynthia A.) > (2015-2019) > Quantifying Short-C...

Quantifying Short-Chain Chlorinated Paraffin Congener Groups

Yuan, Bo (författare)
Stockholms universitet,Institutionen för miljövetenskap och analytisk kemi
Bogdal, Christian (författare)
Berger, Urs (författare)
visa fler...
MacLeod, Matthew (författare)
Stockholms universitet,Institutionen för miljövetenskap och analytisk kemi
Gebbink, Wouter A. (författare)
Alsberg, Tomas (författare)
Stockholms universitet,Institutionen för miljövetenskap och analytisk kemi
de Wit, Cynthia A. (författare)
Stockholms universitet,Institutionen för miljövetenskap och analytisk kemi
visa färre...
 (creator_code:org_t)
2017-08-28
2017
Engelska.
Ingår i: Environmental Science and Technology. - : American Chemical Society (ACS). - 0013-936X .- 1520-5851. ; 51:18, s. 10633-10641
  • Tidskriftsartikel (refereegranskat)
Abstract Ämnesord
Stäng  
  • Accurate quantification of short-chain chlorinated paraffins (SCCPs) poses an exceptional challenge to analytical chemists. SCCPs are complex mixtures of chlorinated alkanes with variable chain length and chlorination level; congeners with a fixed chain length (n) and number of chlorines (m) are referred to as a congener group CnClm Recently, we resolved individual CnClm by mathematically deconvolving soft ionization high-resolution mass spectra of SCCP mixtures. Here we extend the method to quantifying CnClm by introducing CnClm specific response factors (RFs) that are calculated from 17 SCCP chain-length standards with a single carbon chain length and variable chlorination level. The signal pattern of each standard is measured on APCI-QTOF-MS. RFs of each CnClm are obtained by pairwise optimization of the normal distribution's fit to the signal patterns of the 17 chain-length standards. The method was verified by quantifying SCCP technical mixtures and spiked environmental samples with accuracies of 82-123% and 76-109%, respectively. The absolute differences between calculated and manufacturer-reported chlorination degrees were 0.9 to 1.0%Cl for SCCP mixtures of 49-71%Cl. The quantification method has been replicated with ECNI magnetic sector MS and ECNI-Q:Orbitrap-MS. CnClm concentrations determined with the three instruments were highly correlated (R-2 > 0.90) with each other.

Ämnesord

TEKNIK OCH TEKNOLOGIER  -- Naturresursteknik (hsv//swe)
ENGINEERING AND TECHNOLOGY  -- Environmental Engineering (hsv//eng)
NATURVETENSKAP  -- Geovetenskap och miljövetenskap (hsv//swe)
NATURAL SCIENCES  -- Earth and Related Environmental Sciences (hsv//eng)

Publikations- och innehållstyp

ref (ämneskategori)
art (ämneskategori)

Hitta via bibliotek

Till lärosätets databas

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Stäng

Kopiera och spara länken för att återkomma till aktuell vy