SwePub
Sök i LIBRIS databas

  Utökad sökning

WFRF:(Simonsson Moa)
 

Sökning: WFRF:(Simonsson Moa) > Dianion diagnostics...

Dianion diagnostics in DESIREE : High-sensitivity detection of C-n(2-) from a sputter ion source

Chartkunchand, Kiattichart C. (författare)
Stockholms universitet,Fysikum
Stockett, Mark H. (författare)
Stockholms universitet,Fysikum
Anderson, Emma K. (författare)
Stockholms universitet,Fysikum
visa fler...
Eklund, Gustav (författare)
Stockholms universitet,Fysikum
Kristiansson, Moa K. (författare)
Stockholms universitet,Fysikum
Kamińska, Magdalena (författare)
Stockholms universitet,Fysikum,Jan Kochanowski University, Poland
de Ruette, Nathalie (författare)
Stockholms universitet,Fysikum
Blom, Mikael (författare)
Stockholms universitet,Fysikum
Björkhage, Mikael (författare)
Stockholms universitet,Fysikum
Källberg, Anders (författare)
Stockholms universitet,Fysikum
Löfgren, Patrik (författare)
Stockholms universitet,Fysikum
Reinhed, Peter (författare)
Stockholms universitet,Fysikum
Rosén, Stefan (författare)
Stockholms universitet,Fysikum
Simonsson, Ansgar (författare)
Stockholms universitet,Fysikum
Zettergren, Henning (författare)
Stockholms universitet,Fysikum
Schmidt, Henning T. (författare)
Stockholms universitet,Fysikum
Cederquist, Henrik (författare)
Stockholms universitet,Fysikum
visa färre...
 (creator_code:org_t)
AIP Publishing, 2018
2018
Engelska.
Ingår i: Review of Scientific Instruments. - : AIP Publishing. - 0034-6748 .- 1089-7623. ; 89:3
  • Tidskriftsartikel (refereegranskat)
Abstract Ämnesord
Stäng  
  • A sputter ion source with a solid graphite target has been used to produce dianions with a focus on carbon cluster dianions, C-n(2-), with n = 7-24. Singly and doubly charged anions from the source were accelerated together to kinetic energies of 10 keV per atomic unit of charge and injected into one of the cryogenic (13 K) ion-beam storage rings of the Double ElectroStatic Ion Ring Experiment facility at Stockholm University. Spontaneous decay of internally hot C-n(2-) dianions injected into the ring yielded C-n(2-) anions with kinetic energies of 20 keV, which were counted with a microchannel plate detector. Mass spectra produced by scanning the magnetic field of a 90 degrees analyzing magnet on the ion injection line reflect the production of internally hot C-7(2-) - C-24(2-) dianions with lifetimes in the range of tens of microseconds to milliseconds. In spite of the high sensitivity of this method, no conclusive evidence of C-6(2-) was found while there was a clear C-7(2-) signal with the expected isotopic distribution. This is consistent with earlier experimental studies and with theoretical predictions. An upper limit is deduced for a C-6(2-) signal that is two orders-of-magnitude smaller than that for C-7(2-). In addition, CnO2- and CnCu2- dianions were detected.

Ämnesord

NATURVETENSKAP  -- Fysik (hsv//swe)
NATURAL SCIENCES  -- Physical Sciences (hsv//eng)

Nyckelord

Physics
fysik

Publikations- och innehållstyp

ref (ämneskategori)
art (ämneskategori)

Hitta via bibliotek

Till lärosätets databas

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Stäng

Kopiera och spara länken för att återkomma till aktuell vy