SwePub
Sök i LIBRIS databas

  Utökad sökning

WFRF:(Novotný Jan)
 

Sökning: WFRF:(Novotný Jan) > Hypersensitivity to...

Hypersensitivity to material and environmental burden as a possible cause of late complications of cardiac implantable electronic devices

Manousek, Jan (författare)
Andrsova, Irena (författare)
Stejskal, Vera (författare)
Stockholms universitet,Institutionen för molekylär biovetenskap, Wenner-Grens institut,Masaryk Universit, Czech Republic
visa fler...
Vlasinova, Jitka (författare)
Sepsi, Milan (författare)
Kuta, Jan (författare)
Klanova, Jana (författare)
Mazik, Michal (författare)
Jarkovsky, Jiri (författare)
Snajdrova, Lenka (författare)
Benesova, Klara (författare)
Novotny, Tomas (författare)
Zadakova, Andrea (författare)
Spinar, Jindrich (författare)
visa färre...
 (creator_code:org_t)
2017-08-02
2018
Engelska.
Ingår i: Europace. - : Oxford University Press (OUP). - 1099-5129 .- 1532-2092. ; 20:9, s. e140-e147
  • Tidskriftsartikel (refereegranskat)
Abstract Ämnesord
Stäng  
  • AimsTo evaluate whether patients with late complications of pacemakers or implantable cardioverter-defibrillators have hypersensitivity reactions to some of the materials used in generators or in electrodes, or to environmental metal burden.Methods and resultsThe cohort consisted of 20 men and 4 women (mean age: 62.3 +/- 17.2 years) who had a history of late complications of implanted devices. The control group involved 25 men and 8 women (mean age: 64.6 +/- 14.0 years) who had comparable devices, but no history of late complications. Lymphocyte transformation test was used to evaluate hypersensitivity to eight metal pollutants (antimony, manganese, mercury, molybdenum, nickel, platinum, tin, and titanium) selected by results of questionnaires on environmental burden, and by material analysis of generators and electrode surfaces. Exposures to metal pollutants were approximately the same in patients and in controls. Titanium alloy used in generators contained at least 99.32% of titanium and trace levels of other metals; higher levels of tin and platinum were detected in electrode surfaces. Hypersensitivity reactions to mercury and tin were significantly more frequent in patients than in controls (patients and controls: mercury: 68.2 and 31.1%, respectively; P = 0.022; tin: 25.0 and 3.2%, respectively; P = 0.035). In contrast, hypersensitivity to manganese was significantly more frequent in controls than in patients (patients and controls: 13.6 and 50.0%, respectively; P = 0.008).ConclusionOur findings suggest a possible relation between hypersensitivity to metals used in implantable devices or to environmental metal burden and the occurrence of their late complications.

Ämnesord

MEDICIN OCH HÄLSOVETENSKAP  -- Klinisk medicin -- Kardiologi (hsv//swe)
MEDICAL AND HEALTH SCIENCES  -- Clinical Medicine -- Cardiac and Cardiovascular Systems (hsv//eng)

Nyckelord

Pacemaker
Implantable cardioverter-defibrillator
Late complication
Metal pollutants
Delayed-type hypersensitivity
Lymphocyte transformation test

Publikations- och innehållstyp

ref (ämneskategori)
art (ämneskategori)

Hitta via bibliotek

  • Europace (Sök värdpublikationen i LIBRIS)

Till lärosätets databas

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Stäng

Kopiera och spara länken för att återkomma till aktuell vy