Ionization quenching in scintillators used for dosimetry of mixed particle fields

Christensen, Jeppe Brage (författare)
Tech Univ Denmark, Ctr Nucl Technol, Roskilde, Denmark
Almhagen, Erik (författare)
Uppsala universitet,Medicinsk strålningsvetenskap,Skandionkliniken, Uppsala, Sweden
Stolarczyk, Liliana (författare)
Skandionkliniken, Uppsala, Sweden;Polish Acad Sci, Inst Nucl Phys, Bronowice Cyclotron Ctr, Krakow, Poland
visa fler...
Vestergaard, Anne (författare)
Aarhus Univ Hosp, Danish Ctr Particle Therapy, Aarhus, Denmark
Bassler, Niels (författare)
Stockholms universitet,Fysikum,Karolinska Institutet, Sweden; Aarhus University Hospital, Denmark,Stockholm Univ, Dept Phys, Med Radiat Phys, Stockholm, Sweden;Karolinska Inst, Dept Oncol & Pathol, Med Radiat Phys, Stockholm, Sweden;Aarhus Univ Hosp, Dept Expt Clin Oncol, Aarhus, Denmark
Andersen, Claus E. (författare)
Tech Univ Denmark, Ctr Nucl Technol, Roskilde, Denmark
visa färre...
 (creator_code:org_t)
2019-04-29
2019
Engelska.
Ingår i: Physics in Medicine and Biology. - : IOP Publishing. - 0031-9155 .- 1361-6560. ; 64:9
  • Tidskriftsartikel (refereegranskat)
Abstract Ämnesord
Stäng  
  • Ionization quenching in ion beam dosimetry is often related to the fluence- or dose-averaged linear energy transfer (LET). Both quantities are however averaged over a wide LET range and a mixed field of primary and secondary ions. We propose a novel method to correct the quenched luminescence in scintillators exposed to ion beams. The method uses the energy spectrum of the primaries and accounts for the varying quenched luminescence in heavy, secondary ion tracks through amorphous track structure theory. The new method is assessed against more traditional approaches by correcting the quenched luminescence response from the BCF-12, BCF-60, and 81-0084 plastic scintillators exposed to a 100 MeV pristine proton beam in order to compare the effects of the averaged LET quantities and the secondary ions. Calculations and measurements show that primary protons constitute more than 92% of the energy deposition but account for more than 95% of the luminescence signal in the scintillators. The quenching corrected luminescence signal is in better agreement with the dose measurement when the secondary particles are taken into account. The Birks model provided the overall best quenching corrections, when the quenching corrected signal is adjusted for the number of free model parameters. The quenching parameter kB for the BCF-12 and BCF-60 scintillators is in agreement with literature values and was found to be kB = (10.6 +/- 0.1) x 10(-2) mu m keV(-1) for the 81-0084 scintillator. Finally, a fluence threshold for the 100 MeV proton beam was calculated to be of the order of 10(10) cm(-2), corresponding to 110 Gy, above which the quenching increases non-linearly and the Birks model no longer is applicable.

Ämnesord

NATURVETENSKAP  -- Fysik (hsv//swe)
NATURAL SCIENCES  -- Physical Sciences (hsv//eng)
MEDICIN OCH HÄLSOVETENSKAP  -- Klinisk medicin -- Radiologi och bildbehandling (hsv//swe)
MEDICAL AND HEALTH SCIENCES  -- Clinical Medicine -- Radiology, Nuclear Medicine and Medical Imaging (hsv//eng)

Nyckelord

plastic scintillator
particle dosimetry
quenching
proton therapy
medicinsk strålningsfysik
Medical Radiation Physics

Publikations- och innehållstyp

ref (ämneskategori)
art (ämneskategori)

Hitta via bibliotek

Till lärosätets databas

Sök utanför SwePub

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Stäng

Kopiera och spara länken för att återkomma till aktuell vy