International Comparison Exercise for Biological Dosimetry after Exposures with Neutrons Performed at Two Irradiation Facilities as Part of the BALANCE Project

Endesfelder, David (författare)
Kulka, Ulrike (författare)
Bucher, Martin (författare)
visa fler...
Giesen, Ulrich (författare)
Garty, Guy (författare)
Beinke, Christina (författare)
Port, Matthias (författare)
Gruel, Gaëtan (författare)
Gregoire, Eric (författare)
Terzoudi, Georgia (författare)
Triantopoulou, Sotiria (författare)
Ainsbury, Elizabeth A. (författare)
Moquet, Jayne (författare)
Sun, Mingzhu (författare)
Prieto, María Jesús (författare)
Domene, Mercedes Moreno (författare)
Barquinero, Joan-Francesc (författare)
Pujol-Canadell, Monica (författare)
Vral, Anne (författare)
Baeyens, Ans (författare)
Wojcik, Andrzej (författare)
Stockholms universitet,Institutionen för molekylär biovetenskap, Wenner-Grens institut,Jan Kochanowski University, Poland
Oestreicher, Ursula (författare)
visa färre...
 (creator_code:org_t)
2024
2024
Engelska.
Ingår i: Cytogenetic and Genome Research. - 1424-8581 .- 1424-859X. ; 163:3-4, s. 163-177
  • Tidskriftsartikel (refereegranskat)
Abstract Ämnesord
Stäng  
  • In the case of a radiological or nuclear event, biological dosimetry can be an important tool to support clinical decision-making. During a nuclear event, individuals might be exposed to a mixed field of neutrons and photons. The composition of the field and the neutron energy spectrum influence the degree of damage to the chromosomes. During the transatlantic BALANCE project, an exposure similar to a Hiroshima-like device at a distance of 1.5 km from the epicenter was simulated and biological dosimetry based on dicentric chromosomes was performed to evaluate the participants ability to discover unknown doses and to test the influence of differences in neutron spectra. In a first step, calibration curves were established by irradiating blood samples with 5 doses in the range of 0 Gy to 4 Gy at two different facilities in Germany (PTB) and USA (CINF). The samples were sent to eight participating laboratories from the RENEB network and dicentric chromosomes were scored by each participant. Next, blood samples were irradiated with 4 blind doses in each of the two facilities and sent to the participants to provide dose estimates based on the established calibration curves. Manual and semi-automatic scoring of dicentric chromosomes were evaluated for their applicability to neutron exposures. Moreover, the biological effectiveness of the neutrons from the two irradiation facilities was compared. The calibration curves from samples irradiated at CINF showed a 1.4 times higher biological effectiveness compared to samples irradiated at PTB. For manual scoring of dicentric chromosomes, the doses of the test samples were mostly successfully resolved based on the calibration curves established during the project. For semi-automatic scoring, the dose estimation for the test samples was less successful. Doses >2 Gy in the calibration curves revealed non-linear associations between dose and dispersion index of the dicentric counts, especially for manual scoring. The differences in the biological effectiveness between the irradiation facilities suggested that the neutron energy spectrum can have a strong impact on the dicentric counts.

Ämnesord

MEDICIN OCH HÄLSOVETENSKAP  -- Medicinska och farmaceutiska grundvetenskaper -- Medicinsk genetik (hsv//swe)
MEDICAL AND HEALTH SCIENCES  -- Basic Medicine -- Medical Genetics (hsv//eng)

Nyckelord

Biological dosimetry
RENEB
Neutrons
Dicentric chromosomes
Biological effectiveness

Publikations- och innehållstyp

ref (ämneskategori)
art (ämneskategori)

Hitta via bibliotek

Till lärosätets databas

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Stäng

Kopiera och spara länken för att återkomma till aktuell vy