SwePub
Sök i LIBRIS databas

  Extended search

id:"swepub:oai:DiVA.org:su-225734"
 

Search: id:"swepub:oai:DiVA.org:su-225734" > Range shifter contr...

  • 1 of 1
  • Previous record
  • Next record
  •    To hitlist
  • Romero-Expósito, MaiteThe Skandion Clinic Uppsala Sweden;Oncology Pathology Department Karolinska Institutet Solna Sweden (author)

Range shifter contribution to neutron exposure of patients undergoing proton pencil beam scanning

  • Article/chapterEnglish2023

Publisher, publication year, extent ...

  • 2023
  • 2023
  • printrdacarrier

Numbers

  • LIBRIS-ID:oai:DiVA.org:su-225734
  • https://urn.kb.se/resolve?urn=urn:nbn:se:su:diva-225734URI
  • https://doi.org/10.1002/mp.16897DOI
  • http://kipublications.ki.se/Default.aspx?queryparsed=id:154423279URI
  • https://urn.kb.se/resolve?urn=urn:nbn:se:uu:diva-518623URI

Supplementary language notes

  • Language:English
  • Summary in:English

Part of subdatabase

Classification

  • Subject category:ref swepub-contenttype
  • Subject category:art swepub-publicationtype

Notes

  • Background: Superficial targets require the use of the lowest energies within the available energy range in proton pencil-beam scanning (PBS) technique. However, the lower efficiency of the energy selection system at these energies and the requirement of a greater number of layers may represent disadvantages for this approach. The alternative is to use a range shifter (RS) at nozzle exit. However, one of the concerns of using this beamline element is that it becomes an additional source of neutrons that could irradiate organs situated far from the target.Purpose: The purpose of this study is to assess the increase in neutron dose due to the RS in proton PBS technique. Additionally, an analytical model for the neutron production is tested.Methods: Two clinical plans, designed to achieve identical target coverage, were created for an anthropomorphic phantom. These plans consisted of a lateral field delivering an absorbed dose of 60 Gy (RBE) to the target. One of the plans employed the RS. The MCNP code was used to simulate the plans, evaluating the distribution of neutron dose equivalent (Hn) and the equivalent dose in organ. In the plan with the RS plan, neutron production from both the patient and the RS were assessed separately. Hn values were also fitted versus the distance to field edge using a Gaussian function.Results: Hn per prescription dose, in the plan using the RS, ranged between 1.4 and 3.7 mSv/Gy at the field edge, whereas doses at 40 cm from the edge ranged from 9.9 to 32 μSv/Gy. These values are 1.2 to 10 times higher compared to those obtained without the RS. Both this factor and the contribution of neutrons originating from the RS increases with the distance from field edge. A triple-Gaussian function was able to reproduce the equivalent dose in organs within a factor of 2, although underestimating the values.Conclusions: The dose deposited in the patient by the neutrons originating from the RS predominantly affects areas away from the target (beyond approximately 25 cm from field edge), resulting in a neutron dose equivalent of the order of mSv. This indicates an overall low neutron contribution from the use of RS in PBS.

Subject headings and genre

Added entries (persons, corporate bodies, meetings, titles ...)

  • Liszka, MalgorzataThe Skandion Clinic Uppsala Sweden (author)
  • Christou, AthanasiaThe Skandion Clinic Uppsala Sweden (author)
  • Toma-Daşu, Iuliana,1972-Stockholms universitet,Fysikum,Oncology Pathology Department Karolinska Institutet Solna Sweden;Medical Radiation Physics Stockholm University Stockholm Sweden(Swepub:su)iuda0736 (author)
  • Dasu, AlexandruThe Skandion Clinic Uppsala Sweden;Medical Radiation Sciences, Department of Immunology, Genetics and Pathology Uppsala University Uppsala Sweden(Swepub:uu)aleda511 (author)
  • The Skandion Clinic Uppsala Sweden;Oncology Pathology Department Karolinska Institutet Solna SwedenThe Skandion Clinic Uppsala Sweden (creator_code:org_t)

Related titles

  • In:Medical physics (Lancaster)0094-2405
  • In:Medical physics2473-4209

Internet link

Find in a library

To the university's database

  • 1 of 1
  • Previous record
  • Next record
  •    To hitlist

Search outside SwePub

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Close

Copy and save the link in order to return to this view