Sökning: L773:0021 9673 >
Air sampling with E...
Air sampling with Empore solid phase extraction membranes and online single-channel desorption/liquid chromatography/mass spectrometry analysis : Determination of volatile and semi-volatile organophosphate esters
-
- Tollbäck, Johanna (författare)
- Stockholms universitet,Institutionen för analytisk kemi
-
- Tamburro, Davide (författare)
- Stockholms universitet,Institutionen för analytisk kemi
-
- Crescenzi, Carlo (författare)
- Stockholms universitet,Institutionen för analytisk kemi
-
visa fler...
-
- Carlsson, Håkan (författare)
- Stockholms universitet,Institutionen för analytisk kemi
-
visa färre...
-
(creator_code:org_t)
- Elsevier BV, 2006
- 2006
- Engelska.
-
Ingår i: Journal of Chromatography A. - : Elsevier BV. - 0021-9673 .- 1873-3778. ; 1129:1, s. 1-8
- Relaterad länk:
-
https://urn.kb.se/re...
-
visa fler...
-
https://doi.org/10.1...
-
visa färre...
Abstract
Ämnesord
Stäng
- A method for determining organophosphate esters in air samples using C8 Empore solid phase extraction (SPE) membranes has been developed. After the sampling the analytes trapped in the membrane are completely desorbed with methanol, using an extraction cell connected online to the organic modifier channel of a HPLC gradient pump. The addition of water to the mobile phase prior to analytical chromatography ensures that the analytes are refocused and efficiently separated. Sampling with Empore SPE membranes enables the collection of analytes in both the vapour phase and particulate matter. During the air sampling procedure no losses were observed after 24 h of sampling, yielding a total volume of 14.4 m3, even for the most volatile compound used in this investigation (trimethylphosphate). Complete desorption was observed for all the organophosphate esters and recoveries were greater than 95%, with a relative standard deviation of less than 8%. The limits of detection ranged between 0.4 and 19 pg/m3. The effect of particulate matter on the extraction efficiency was investigated in detail by spiking the membranes with reference standard material. It was also found that the SPE membranes could be stored for at least 5 days at room temperature without any evidence of loss. The efficacy of the method was verified using real samples from different common indoor environments. Interestingly, significant quantities of several phosphate esters were found in a NIST standard reference material (urban dust, SRM 1649a).
Ämnesord
- NATURVETENSKAP -- Kemi -- Analytisk kemi (hsv//swe)
- NATURAL SCIENCES -- Chemical Sciences -- Analytical Chemistry (hsv//eng)
Nyckelord
- Air sampling; Air analysis; Online; Single-channel desorption; Dynamic solvent extraction; Extraction methods; LC-MS; Volatile; Semi-volatile; Organophosphate esters; Empore disk; Solid phase extraction; SPE; Membranes; Particulate matter; Urban dust; Environmental analysis; Organophosphorus compounds; Phosphate
- Analytical chemistry
- Analytisk kemi
- Analytical Chemistry
- analytisk kemi
Publikations- och innehållstyp
- ref (ämneskategori)
- art (ämneskategori)
Hitta via bibliotek
Till lärosätets databas