SwePub
Sök i LIBRIS databas

  Utökad sökning

L773:1107 0625
 

Sökning: L773:1107 0625 > Comparison of the 3...

Comparison of the 3D-conformal, helical tomotherapy and multileaf collimators-based intensity modulated radiotherapy modalities using radiobiological measures

Mavroidis, P. (författare)
Stockholms universitet
Ferreira, B. Costa (författare)
Stockholms universitet
Shi, C. (författare)
visa fler...
Lind, B. K. (författare)
Papanikolaou, N. (författare)
visa färre...
 (creator_code:org_t)
2008
2008
Engelska.
Ingår i: JOURNAL OF BUON. - 1107-0625. ; 13:1, s. 75-86
  • Tidskriftsartikel (refereegranskat)
Abstract Ämnesord
Stäng  
  • Purpose: Intensity modulated radiotherapy (IMRT) using multileaf collimators (MLC) and helical tomotherapy (HT) have become increasingly popular over the past few years. However their clinical efficacy and effectiveness continue to be investigated. In order to provide a more thorough evaluation and comparison of treatment plans, the utilization of the biologically effective uniform dose (D) together with the complication-free tumor control probability (P+) are examined. Materials and methods:In this study, a typical case of lung cancer was investigated by developing a 3D conformal treatment plan, a linac MLC-based step-and-shoot IMRT plan and a HT plan. The 3 different treatment plans were compared based on radiobiological measures by using the P+ index and the D concept as the common prescription point of the plans and plotting the tissue response probabilities vs. D for a range of prescription doses. Results: The applied plan evaluation method showed that in this lung cancer case the MLC-based IMRT plan was best over the clinically useful dose prescription range. The 3D-conformal, MLC-based IMRT and HT treatment plans gave a P+ of 55.4%, 72.9% and 66.9%, for a D to the internal target volume (ITV) of 57.0 Gy, 66.9 Gy and 64.0 Gy, respectively. Conclusion: In comparison to 3D conformal radiotherapy, both Affi based-IMRT and HT can better encompass the often large ITV required while minimizing the volume of the organs at risk receiving high dose. Taking into account the dose-response relations of the irradiated tumors and normal tissues, a radiobiological treatment plan evaluation can be performed, which may provide a closer association of the delivered treatment with the clinical outcome.

Nyckelord

biologically effective uniform dose
conformal radiotherapy
complication-free tumor control
dose-response relations
helical tomotherapy
radiobiological evaluation

Publikations- och innehållstyp

ref (ämneskategori)
art (ämneskategori)

Hitta via bibliotek

Till lärosätets databas

Sök utanför SwePub

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Stäng

Kopiera och spara länken för att återkomma till aktuell vy