SwePub
Sök i LIBRIS databas

  Utökad sökning

WFRF:(de Wit Cynthia A.)
 

Sökning: WFRF:(de Wit Cynthia A.) > (2010-2014) > Comparisons of poly...

Comparisons of polybrominated diphenyl ether and hexabromocyclododecane concentrations in dust collected with two sampling methods and matched breast milk samples

Björklund, Justina A. (författare)
Stockholms universitet,Institutionen för tillämpad miljövetenskap (ITM)
Sellström, Ulla (författare)
Stockholms universitet,Institutionen för tillämpad miljövetenskap (ITM)
de Wit, Cynthia A. (författare)
Stockholms universitet,Institutionen för tillämpad miljövetenskap (ITM)
visa fler...
Aune, M. (författare)
Lignell, S. (författare)
Karolinska Institutet
Darnerud, P. O. (författare)
visa färre...
 (creator_code:org_t)
2012-01-27
2012
Engelska.
Ingår i: Indoor Air. - : Hindawi Limited. - 0905-6947 .- 1600-0668. ; 22:4, s. 279-288
  • Tidskriftsartikel (refereegranskat)
Abstract Ämnesord
Stäng  
  • Household dust from 19 Swedish homes was collected using two different sampling methods: from the occupants own home vacuum cleaner after insertion of a new bag and using a researcher-collected method where settled house dust was collected from surfaces above floor level. The samples were analyzed for 16 polybrominated diphenyl ether (PBDE) congeners and total hexabromocyclododecane (HBCD). Significant correlations (r = 0.600.65, Spearman r = 0.470.54, P < 0.05) were found between matched dust samples collected with the two sampling methods for ?OctaBDE and ?DecaBDE but not for ?PentaBDE or HBCD. Statistically significantly higher concentrations of all PBDE congeners were found in the researcher-collected dust than in the home vacuum cleaner bag dust (VCBD). For HBCD, however, the concentrations were significantly higher in the home VCBD samples. Analysis of the bags themselves indicated no or very low levels of PBDEs and HBCD. This indicates that there may be specific HBCD sources to the floor and/or that it may be present in the vacuum cleaners themselves. The BDE-47 concentrations in matched pairs of VCBD and breast milk samples were significantly correlated (r = 0.514, P = 0.029), indicating that one possible exposure route for this congener may be via dust ingestion. Practical Implications The statistically significant correlations found for several individual polybrominated diphenyl ether (PBDE) congeners, ?OctaBDE and ?DecaBDE between the two dust sampling methods in this study indicate that the same indoor sources contaminate both types of dust or that common processes govern the distribution of these compounds in the indoor environment. Therefore, either method is adequate for screening ?OctaBDE and ?DecaBDE in dust. The high variability seen between dust samples confirms results seen in other studies. For hexabromocyclododecane (HBCD), divergent results in the two dust types indicate differences in contamination sources to the floor than to above-floor surfaces. Thus, it is still unclear which dust sampling method is most relevant for HBCD as well as for ?PentaBDE in dust and, further, which is most relevant for determining human exposure to PBDEs and HBCD.

Ämnesord

MEDICIN OCH HÄLSOVETENSKAP  -- Hälsovetenskap -- Arbetsmedicin och miljömedicin (hsv//swe)
MEDICAL AND HEALTH SCIENCES  -- Health Sciences -- Occupational Health and Environmental Health (hsv//eng)
NATURVETENSKAP  -- Kemi (hsv//swe)
NATURAL SCIENCES  -- Chemical Sciences (hsv//eng)

Nyckelord

Dust sampling
Brominated flame retardants
Human breast milk
Human exposure

Publikations- och innehållstyp

ref (ämneskategori)
art (ämneskategori)

Hitta via bibliotek

Till lärosätets databas

Sök utanför SwePub

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Stäng

Kopiera och spara länken för att återkomma till aktuell vy