First experimental evaluation of a high-resolution deep silicon photon-counting sensor

Brunskog, Rickard (författare)
KTH,Medicinsk bildfysik,Karolinska University Hospital, MedTechLabs, BioClinicum, Solna, Sweden
Persson, Mats, 1987- (författare)
KTH,Medicinsk bildfysik,Karolinska University Hospital, MedTechLabs, BioClinicum, Solna, Sweden
Jin, Zihui (författare)
KTH,Medicinsk bildfysik
visa fler...
Danielsson, Mats, Professor (författare)
KTH,Medicinsk bildfysik,Karolinska University Hospital, MedTechLabs, BioClinicum, Solna, Sweden
visa färre...
 (creator_code:org_t)
SPIE-Intl Soc Optical Eng, 2024
2024
Engelska.
Ingår i: Journal of Medical Imaging. - : SPIE-Intl Soc Optical Eng. - 2329-4302 .- 2329-4310. ; 11:1
  • Tidskriftsartikel (refereegranskat)
Abstract Ämnesord
Stäng  
  • Purpose: Current photon-counting computed tomography detectors are limited to a pixel size of around 0.3 to 0.5 mm due to excessive charge sharing degrading the dose efficiency and energy resolution as the pixels become smaller. In this work, we present measurements of a prototype photon-counting detector that leverages the charge sharing to reach a theoretical sub-pixel resolution in the order of 1 μm. The goal of the study is to validate our Monte-Carlo simulation using measurements, enabling further development. Approach: We measure the channel response at the MAX IV Lab, in the DanMAX beamline, with a 35 keV photon beam, and compare the measurements with a 2D Monte Carlo simulation combined with a charge transport model. Only a few channels on the prototype are connected to keep the number of wire bonds low. Results: The measurements agree generally well with the simulations with the beam close to the electrodes but diverge as the beam is moved further away. The induced charge cloud signals also seem to increase linearly as the beam is moved away from the electrodes. Conclusions: The agreement between measurements and simulations indicates that the Monte-Carlo simulation can accurately model the channel response of the detector with the photon interactions close to the electrodes, which indicates that the unconnected electrodes introduce unwanted effects that need to be further explored. With the same Monte-Carlo simulation previously indicating a resolution of around 1 μm with similar geometry, the results are promising that an ultra-high resolution detector is not far in the future.

Ämnesord

TEKNIK OCH TEKNOLOGIER  -- Medicinteknik -- Annan medicinteknik (hsv//swe)
ENGINEERING AND TECHNOLOGY  -- Medical Engineering -- Other Medical Engineering (hsv//eng)

Nyckelord

computed tomography
deep silicon
photon-counting
ultra-high resolution

Publikations- och innehållstyp

ref (ämneskategori)
art (ämneskategori)

Hitta via bibliotek

Till lärosätets databas

Sök utanför SwePub

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Stäng

Kopiera och spara länken för att återkomma till aktuell vy