Differential laser-induced thermoelastic spectroscopy for dual-gas CO2/CH4 detection
-
- Cheng, Yaopeng (författare)
- Zhejiang Univ, Coll Opt Sci & Engn, Ctr Opt & Electromagnet Res, Hangzhou 310058, Peoples R China.;Zhejiang Univ, Taizhou Hosp, Taizhou 318000, Peoples R China.
-
- Xu, Yinghe (författare)
- Zhejiang Univ, Taizhou Hosp, Taizhou 318000, Peoples R China.
-
- Chen, Ting (författare)
- Zhejiang Inst Metrol, Hangzhou 310058, Peoples R China.
-
visa fler...
-
- Mei, Huaiyu (författare)
- Zhejiang Univ, Coll Opt Sci & Engn, Ctr Opt & Electromagnet Res, Hangzhou 310058, Peoples R China.
-
- He, Sailing (författare)
- KTH,Elektromagnetism och fusionsfysik,Zhejiang Univ, Taizhou Hosp, Taizhou 318000, Peoples R China.;Zhejiang Univ, Natl Engn Res Ctr Opt Instruments, Hangzhou 310058, Peoples R China.;Zhejiang Univ, Shanghai Inst Adv Study, Shanghai 200135, Peoples R China.
-
visa färre...
-
Zhejiang Univ, Coll Opt Sci & Engn, Ctr Opt & Electromagnet Res, Hangzhou 310058, Peoples R China;Zhejiang Univ, Taizhou Hosp, Taizhou 318000, Peoples R China. Zhejiang Univ, Taizhou Hosp, Taizhou 318000, Peoples R China. (creator_code:org_t)
- Elsevier BV, 2025
- 2025
- Engelska.
-
Ingår i: Measurement. - : Elsevier BV. - 0263-2241 .- 1873-412X. ; 240
- Relaterad länk:
-
https://urn.kb.se/re...
-
visa fler...
-
https://doi.org/10.1...
-
visa färre...
Abstract
Ämnesord
Stäng
- A novel differential laser-induced thermoelastic spectroscopy (D-LITES) was demonstrated. In D-LITES, one probe and one control laser beam with different modulation phases were combined to generate two quartz tuning fork (QTF) mechanical oscillations, which are pi out of phase. The powers of the two lasers were adjusted to balance out the background noise. The differential signal was acquired by demodulating the QTF piezoelectric signal. The D-LITES sensor had a compact and cost-effective one-path configuration and was able to realize dualgas detection. Carbon dioxide (CO2) and methane (CH4) were chosen as target gases to verify the D-LITES sensor performance. With the D-LITES technique, the background noise was greatly suppressed. The minimum detection limit (MDL) was improved by 9 times from 260 ppm to 29 ppm and 7.13 times from 0.385 ppm to 0.054 ppm for CO2 and CH4 detection, respectively.
Ämnesord
- NATURVETENSKAP -- Fysik -- Atom- och molekylfysik och optik (hsv//swe)
- NATURAL SCIENCES -- Physical Sciences -- Atom and Molecular Physics and Optics (hsv//eng)
Nyckelord
- QTF
- LITES
- Differential detection
- Background elimination