Accuracy of inverse treatment planning on substitute CT images derived from MR data for brain lesions

Jonsson, Joakim H. (författare)
Umeå universitet,Institutionen för strålningsvetenskaper
Akhtari, Mohammad M. (författare)
Umeå universitet,Institutionen för strålningsvetenskaper
Karlsson, Magnus G. (författare)
Umeå universitet,Institutionen för strålningsvetenskaper
visa fler...
Johansson, Adam (författare)
Umeå universitet,Institutionen för strålningsvetenskaper
Asklund, Thomas (författare)
Umeå universitet,Institutionen för strålningsvetenskaper
Nyholm, Tufve (författare)
Umeå universitet,Institutionen för strålningsvetenskaper
visa färre...
 (creator_code:org_t)
2015-01-10
2015
Engelska.
Ingår i: Radiation Oncology. - : Springer Science and Business Media LLC. - 1748-717X. ; 10
  • Tidskriftsartikel (refereegranskat)
Abstract Ämnesord
Stäng  
  • Background: In this pilot study we evaluated the performance of a substitute CT (s-CT) image derived from MR data of the brain, as a basis for optimization of intensity modulated rotational therapy, final dose calculation and derivation of reference images for patient positioning. Methods: S-CT images were created using a Gaussian mixture regression model on five patients previously treated with radiotherapy. Optimizations were compared using D-max, D-min, D-median and D-mean measures for the target volume and relevant risk structures. Final dose calculations were compared using gamma index with 1%/1 mm and 3%/3 mm acceptance criteria. 3D geometric evaluation was conducted using the DICE similarity coefficient for bony structures. 2D geometric comparison of digitally reconstructed radiographs (DRRs) was performed by manual delineation of relevant structures on the s-CT DRR that were transferred to the CT DRR and compared by visual inspection. Results: Differences for the target volumes in optimization comparisons were small in general, e.g. a mean difference in both D-min and D-max within similar to 0.3%. For the final dose calculation gamma evaluations, 100% of the voxels passed the 1%/1 mm criterion within the PTV. Within the entire external volume between 99.4% and 100% of the voxels passed the 3%/3 mm criterion. In the 3D geometric comparison, the DICE index varied between approximately 0.8-0.9, depending on the position in the skull. In the 2D DRR comparisons, no appreciable visual differences were found. Conclusions: Even though the present work involves a limited number of patients, the results provide a strong indication that optimization and dose calculation based on s-CT data is accurate regarding both geometry and dosimetry.

Ämnesord

MEDICIN OCH HÄLSOVETENSKAP  -- Klinisk medicin -- Cancer och onkologi (hsv//swe)
MEDICAL AND HEALTH SCIENCES  -- Clinical Medicine -- Cancer and Oncology (hsv//eng)
MEDICIN OCH HÄLSOVETENSKAP  -- Klinisk medicin -- Radiologi och bildbehandling (hsv//swe)
MEDICAL AND HEALTH SCIENCES  -- Clinical Medicine -- Radiology, Nuclear Medicine and Medical Imaging (hsv//eng)

Nyckelord

Radiotherapy
Treatment planning
MRI
Substitute CT
s-CT

Publikations- och innehållstyp

ref (ämneskategori)
art (ämneskategori)

Hitta via bibliotek

Till lärosätets databas

Sök utanför SwePub

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Stäng

Kopiera och spara länken för att återkomma till aktuell vy