SwePub
Sök i LIBRIS databas

  Utökad sökning

WFRF:(Åberg Anna)
 

Sökning: WFRF:(Åberg Anna) > Outcome of microdia...

Outcome of microdialysis sampling on liver surface and parenchyma

Abrahamsson, Pernilla (författare)
Umeå universitet,Anestesiologi och intensivvård
Johansson, Göran (författare)
Umeå universitet,Anestesiologi och intensivvård
Åberg, Anna-Maja (författare)
Umeå universitet,Anestesiologi och intensivvård
visa fler...
Winsö, Ola (författare)
Umeå universitet,Anestesiologi och intensivvård
Blind, Per Jonas (författare)
Umeå universitet,Kirurgi
visa färre...
 (creator_code:org_t)
Elsevier BV, 2016
2016
Engelska.
Ingår i: Journal of Surgical Research. - : Elsevier BV. - 0022-4804 .- 1095-8673. ; 200:2, s. 480-487
  • Tidskriftsartikel (refereegranskat)
Abstract Ämnesord
Stäng  
  • Background: To investigate whether surface microdialysis (μD) sampling in probes covered by a plastic film, as compared to noncovered and to intraparenchymatous probes, would increase the technique's sensitivity for pathophysiologic events occurring in a liver ischemia-reperfusion model. Placement of μD probes in the parenchyma of an organ, as is conventionally done, may cause adverse effects, e.g., bleeding, possibly influencing outcome.Methods: A transient ischemia-reperfusion model of the liver was used in six anesthetized normoventilated pigs. μD probes were placed in the parenchyma and on the liver surface. Surface probes were either left uncovered or were covered by plastic film.Results: Lactate and glucose levels were significantly higher in plastic film covered probes than in uncovered surface probes throughout the ischemic period. Glycerol levels were significantly higher in plastic film covered probes than in uncovered surface probes at 30 and 45 min into ischemia.Conclusions: Covering the μD probe increases the sensibility of the μD–technique in monitoring an ischemic insult and reperfusion in the liver. These findings confirm that the principle of surface μD works, possibly replacing need of intraparenchymatous placement of μD probes. Surface μD seemingly allows, noninvasively from an organ's surface, via the extracellular compartment, assessment of intracellular metabolic events. The finding that covered surface μD probes allows detection of local metabolic changes earlier than do intraparenchymatous probes, merit further investigation focusing on μD probe design.

Ämnesord

MEDICIN OCH HÄLSOVETENSKAP  -- Medicinska och farmaceutiska grundvetenskaper -- Fysiologi (hsv//swe)
MEDICAL AND HEALTH SCIENCES  -- Basic Medicine -- Physiology (hsv//eng)
MEDICIN OCH HÄLSOVETENSKAP  -- Medicinsk bioteknologi -- Biomedicinsk laboratorievetenskap/teknologi (hsv//swe)
MEDICAL AND HEALTH SCIENCES  -- Medical Biotechnology -- Biomedical Laboratory Science/Technology (hsv//eng)
MEDICIN OCH HÄLSOVETENSKAP  -- Klinisk medicin -- Kirurgi (hsv//swe)
MEDICAL AND HEALTH SCIENCES  -- Clinical Medicine -- Surgery (hsv//eng)

Nyckelord

Microdialysis
Liver
Ischemia
Reperfusion
Surface probe
Metabolism

Publikations- och innehållstyp

ref (ämneskategori)
art (ämneskategori)

Hitta via bibliotek

Till lärosätets databas

Hitta mer i SwePub

Av författaren/redakt...
Abrahamsson, Per ...
Johansson, Göran
Åberg, Anna-Maja
Winsö, Ola
Blind, Per Jonas
Om ämnet
MEDICIN OCH HÄLSOVETENSKAP
MEDICIN OCH HÄLS ...
och Medicinska och f ...
och Fysiologi
MEDICIN OCH HÄLSOVETENSKAP
MEDICIN OCH HÄLS ...
och Medicinsk biotek ...
och Biomedicinsk lab ...
MEDICIN OCH HÄLSOVETENSKAP
MEDICIN OCH HÄLS ...
och Klinisk medicin
och Kirurgi
Artiklar i publikationen
Journal of Surgi ...
Av lärosätet
Umeå universitet

Sök utanför SwePub

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Stäng

Kopiera och spara länken för att återkomma till aktuell vy