SwePub
Sök i LIBRIS databas

  Utökad sökning

L773:1522 1709
 

Sökning: L773:1522 1709 > Changes in lower in...

Changes in lower incisor irregularity during treatment with oral sleep apnea appliances

Norrhem, Niclas (författare)
Umeå universitet,Institutionen för odontologi,Folktandvården Skåne, Lund, Sweden
Nemeczek, Hans (författare)
Umeå universitet,Institutionen för odontologi
Marklund, Marie (författare)
Umeå universitet,Institutionen för odontologi
 (creator_code:org_t)
2017-01-23
2017
Engelska.
Ingår i: Sleep and Breathing. - : Springer. - 1520-9512 .- 1522-1709. ; 21:3, s. 607-613
  • Tidskriftsartikel (refereegranskat)
Abstract Ämnesord
Stäng  
  • Purpose: The purpose of this study is to test the hypothesis that a flexible oral appliance without incisor coverage (OAFlex) increases the irregularity of the front teeth compared with a rigid appliance with incisor coverage (OARigid) in patients treated for obstructive sleep apnea (OSA).Method and patients: Nineteen patients (10 men) who had used OARigid and 22 patients (19 men) who had used OAFlex with a median age of 61 years (IQR of 56 to 67 years) who had been treated during a median period of 2.9 years (IQR of 2.7 to 3.1 years) were included in the study. There was no difference in age (p = 0.601) or treatment time (p = 0.432) between the two appliance groups. The patients had clinical examinations, responded to a questionnaire, and had impressions taken for plaster casts. The irregularity of the front teeth was measured by Little’s Index, where the combined linear displacement of all the front teeth is assessed. Changes between baseline and follow-up were compared between the two groups.Results: The OAFlex group increased the irregularity of their lower front teeth by 0.3 mm (p = 0.018), while the OARigid group had unchanged frontal irregularity (p = 0.717). The difference between the groups was significant (p = 0.035). There were no changes in the irregularity of the upper front teeth in either group. Patient satisfaction with treatment did not differ between the two appliances.Conclusions: The present results support the hypothesis that a flexible OA without incisor coverage increases the irregularity of the lower front teeth compared with a rigid OA with incisor coverage.

Ämnesord

MEDICIN OCH HÄLSOVETENSKAP  -- Klinisk medicin -- Odontologi (hsv//swe)
MEDICAL AND HEALTH SCIENCES  -- Clinical Medicine -- Dentistry (hsv//eng)

Nyckelord

Oral appliances
Mandibular advancement devices
Side effects
Appliance design

Publikations- och innehållstyp

ref (ämneskategori)
art (ämneskategori)

Hitta via bibliotek

Till lärosätets databas

Hitta mer i SwePub

Av författaren/redakt...
Norrhem, Niclas
Nemeczek, Hans
Marklund, Marie
Om ämnet
MEDICIN OCH HÄLSOVETENSKAP
MEDICIN OCH HÄLS ...
och Klinisk medicin
och Odontologi
Artiklar i publikationen
Sleep and Breath ...
Av lärosätet
Umeå universitet

Sök utanför SwePub

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Stäng

Kopiera och spara länken för att återkomma till aktuell vy