SwePub
Sök i LIBRIS databas

  Extended search

id:"swepub:oai:DiVA.org:umu-132427"
 

Search: id:"swepub:oai:DiVA.org:umu-132427" > Power-performance t...

  • 1 of 1
  • Previous record
  • Next record
  •    To hitlist
  • Krzywda, Jakub,1989-Umeå universitet,Institutionen för datavetenskap,Distributed Systems,Umea Univ, Dept Comp Sci, SE-90187 Umea, Sweden. (author)

Power-performance tradeoffs in data center servers : DVFS, CPUpinning, horizontal, and vertical scaling

  • Article/chapterEnglish2018

Publisher, publication year, extent ...

  • Elsevier BV,2018
  • printrdacarrier

Numbers

  • LIBRIS-ID:oai:DiVA.org:umu-132427
  • https://urn.kb.se/resolve?urn=urn:nbn:se:umu:diva-132427URI
  • https://doi.org/10.1016/j.future.2017.10.044DOI
  • https://urn.kb.se/resolve?urn=urn:nbn:se:uu:diva-345707URI

Supplementary language notes

  • Language:English
  • Summary in:English

Part of subdatabase

Classification

  • Subject category:ref swepub-contenttype
  • Subject category:art swepub-publicationtype

Notes

  • Originally published in thesis in manuscript form.
  • Dynamic Voltage and Frequency Scaling (DVFS), CPU pinning, horizontal, and vertical scaling, are four techniques that have been proposed as actuators to control the performance and energy consumption on data center servers. This work investigates the utility of these four actuators, and quantifies the power-performance tradeoffs associated with them. Using replicas of the German Wikipedia running on our local testbed, we perform a set of experiments to quantify the influence of DVFS, vertical and horizontal scaling, and CPU pinning on end-to-end response time (average and tail), throughput, and power consumption with different workloads. Results of the experiments show that DVFS rarely reduces the power consumption of underloaded servers by more than 5%, but it can be used to limit the maximal power consumption of a saturated server by up to 20% (at a cost of performance degradation). CPU pinning reduces the power consumption of underloaded server (by up to 7%) at the cost of performance degradation, which can be limited by choosing an appropriate CPU pinning scheme. Horizontal and vertical scaling improves both the average and tail response time, but the improvement is not proportional to the amount of resources added. The load balancing strategy has a big impact on the tail response time of horizontally scaled applications.

Subject headings and genre

Added entries (persons, corporate bodies, meetings, titles ...)

  • Ali-Eldin, AhmedUmeå universitet,Institutionen för datavetenskap,Distributed Systems,Umea Univ, Dept Comp Sci, SE-90187 Umea, Sweden.(Swepub:umu)ahal0005 (author)
  • Carlson, Trevor E.Uppsala universitet,Datorteknik,Natl Univ Singapore, Sch Comp, 13 Comp Dr, Singapore 117417, Singapore,Umea Univ, Dept Comp Sci, SE-90187 Umea, Sweden.(Swepub:uu)treca854 (author)
  • Östberg, Per-OlovUmeå universitet,Institutionen för datavetenskap,Distributed Systems,Umea Univ, Dept Comp Sci, SE-90187 Umea, Sweden.(Swepub:umu)pooosg92 (author)
  • Elmroth, ErikUmeå universitet,Institutionen för datavetenskap,Distributed Systems(Swepub:umu)erel0001 (author)
  • Umeå universitetInstitutionen för datavetenskap (creator_code:org_t)

Related titles

  • In:Future generations computer systems: Elsevier BV81, s. 114-1280167-739X1872-7115

Internet link

Find in a library

To the university's database

  • 1 of 1
  • Previous record
  • Next record
  •    To hitlist

Search outside SwePub

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Close

Copy and save the link in order to return to this view