SwePub
Sök i LIBRIS databas

  Utökad sökning

WFRF:(Lindahl Olof A.)
 

Sökning: WFRF:(Lindahl Olof A.) > Sensitivity improve...

  • Murayama, YoshinobuDepartment of Electrical and Electronics Engineering, College of Engineering , Nihon University (författare)

Sensitivity improvements of a resonance-based tactile sensor.

  • Artikel/kapitelEngelska2017

Förlag, utgivningsår, omfång ...

  • 2016-10-05
  • Informa UK Limited,2017
  • printrdacarrier

Nummerbeteckningar

  • LIBRIS-ID:oai:DiVA.org:umu-133977
  • https://urn.kb.se/resolve?urn=urn:nbn:se:umu:diva-133977URI
  • https://doi.org/10.1080/03091902.2016.1239278DOI
  • https://urn.kb.se/resolve?urn=urn:nbn:se:ltu:diva-59615URI

Kompletterande språkuppgifter

  • Språk:engelska
  • Sammanfattning på:engelska

Ingår i deldatabas

Klassifikation

  • Ämneskategori:ref swepub-contenttype
  • Ämneskategori:art swepub-publicationtype

Anmärkningar

  • Validerad; 2017; Nivå 2; 2016-12-20 (andbra)
  • Resonance-based contact-impedance measurement refers to the application of resonance sensors based on the measurement of the changes in the resonance curve of an ultrasonic resonator in contact with a surface. The advantage of the resonance sensor is that it is very sensitive to small changes in the contact impedance. A sensitive micro tactile sensor (MTS) was developed, which measured the elasticity of soft living tissues at the single-cell level. In the present paper, we studied the method of improving the touch and stiffness sensitivity of the MTS. First, the dependence of touch sensitivity in relation to the resonator length was studied by calculating the sensitivity coefficient at each length ranging from 9 to 40 mm. The highest touch sensitivity was obtained with a 30-mm-long glass needle driven at a resonance frequency of 100 kHz. Next, the numerical calculation of contact impedance showed that the highest stiffness sensitivity was achieved when the driving frequency was 100 kHz and the contact-tip diameter of the MTS was 10 μm. The theoretical model was then confirmed experimentally using a phase-locked-loop-based digital feedback oscillation circuit. It was found that the developed MTS, whose resonant frequency was 97.030 kHz, performed with the highest sensitivity of 53.2 × 10(6) Hz/N at the driving frequency of 97.986 kHz, i.e. the highest sensitivity was achieved at 956 Hz above the resonant frequency.

Ämnesord och genrebeteckningar

Biuppslag (personer, institutioner, konferenser, titlar ...)

  • Lindahl, Olof ALuleå tekniska universitet,Umeå universitet,Institutionen för strålningsvetenskaper,Strömningslära och experimentell mekanik(Swepub:ltu)olofl (författare)
  • Department of Electrical and Electronics Engineering, College of Engineering , Nihon UniversityInstitutionen för strålningsvetenskaper (creator_code:org_t)

Sammanhörande titlar

  • Ingår i:Journal of Medical Engineering & Technology: Informa UK Limited41:2, s. 131-1400309-19021464-522X

Internetlänk

Hitta via bibliotek

Till lärosätets databas

Hitta mer i SwePub

Av författaren/redakt...
Murayama, Yoshin ...
Lindahl, Olof A
Om ämnet
MEDICIN OCH HÄLSOVETENSKAP
MEDICIN OCH HÄLS ...
och Klinisk medicin
och Radiologi och bi ...
TEKNIK OCH TEKNOLOGIER
TEKNIK OCH TEKNO ...
och Maskinteknik
och Teknisk mekanik
Artiklar i publikationen
Journal of Medic ...
Av lärosätet
Umeå universitet
Luleå tekniska universitet

Sök utanför SwePub

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Stäng

Kopiera och spara länken för att återkomma till aktuell vy