Motion corrected DWI with integrated T2-mapping for simultaneous estimation of ADC, T2-relaxation and perfusion in prostate cancer

Skorpil, Mikael (author)
Umeå universitet,Institutionen för strålningsvetenskaper,Department of Radiology, Uppsala University Hospital, Uppsala, Sweden,Umeå Univ, Dept Radiat Sci, Umeå, Sweden.
Brynolfsson, Patrik (author)
Umeå universitet,Institutionen för strålningsvetenskaper,Umeå Univ, Dept Radiat Sci, Umeå, Sweden.
Engström, M. (author)
GE Healthcare, Appl Sci Lab, Uppsala, Sweden.
 (creator_code:org_t)
Elsevier, 2017
2017
English.
In: Magnetic Resonance Imaging. - : Elsevier. - 0730-725X .- 1873-5894. ; 39, s. 162-167
  • Journal article (peer-reviewed)
Abstract Subject headings
Close  
  • Objective: Multiparametric magnetic resonance imaging (MRI) and PI-RADS (Prostate Imaging - Reporting and Data System) has become the standard to determine a probability score for a lesion being a clinically significant prostate cancer. T2-weighted and diffusion-weighted imaging (DWI) are essential in PI-RADS, depending partly on visual assessment of signal intensity, while dynamic-contrast enhanced imaging is less important. To decrease inter-rater variability and further standardize image evaluation, complementary objective measures are in need. Methods: We here demonstrate a sequence enabling simultaneous quantification of apparent diffusion coefficient (ADC) and T2-relaxation, as well as calculation of the perfusion fraction f from low b-value intravoxel incoherent motion data. Expandable wait pulses were added to a FOCUS DW SE-EPI sequence, allowing the effective echo time to change at run time. To calculate both ADC and f, b-values 200 s/mm(2) and 600 s/mm(2) were chosen, and for T2-estimation 6 echo times between 64.9 ms and 114.9 ms were used. Results: Three patients with prostate cancer were examined and all had significantly decreased ADC and T2 values, while f was significantly increased in 2 of 3 tumors. T2 maps obtained in phantom measurements and in a healthy volunteer were compared to T2 maps from a SE sequence with consecutive scans, showing good agreement. In addition, a motion correction procedure was implemented to reduce the effects of prostate motion, which improved T2-estimation. Conclusions: This sequence could potentially enable more objective tumor grading, and decrease the inter-rater variability in the PI-RADS classification.

Subject headings

MEDICIN OCH HÄLSOVETENSKAP  -- Klinisk medicin -- Radiologi och bildbehandling (hsv//swe)
MEDICAL AND HEALTH SCIENCES  -- Clinical Medicine -- Radiology, Nuclear Medicine and Medical Imaging (hsv//eng)
TEKNIK OCH TEKNOLOGIER  -- Medicinteknik -- Medicinsk laboratorie- och mätteknik (hsv//swe)
ENGINEERING AND TECHNOLOGY  -- Medical Engineering -- Medical Laboratory and Measurements Technologies (hsv//eng)

Keyword

Prostate cancer
Apparent diffusion coefficient
Diffusion weighted imaging
T2-relaxation
Magnetic resonance imaging
Perfusion

Publication and Content Type

ref (subject category)
art (subject category)

Find in a library

To the university's database

Find more in SwePub

By the author/editor
Skorpil, Mikael
Brynolfsson, Pat ...
Engström, M.
About the subject
MEDICAL AND HEALTH SCIENCES
MEDICAL AND HEAL ...
and Clinical Medicin ...
and Radiology Nuclea ...
ENGINEERING AND TECHNOLOGY
ENGINEERING AND ...
and Medical Engineer ...
and Medical Laborato ...
Articles in the publication
Magnetic Resonan ...
By the university
Umeå University
Uppsala University

Search outside SwePub

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Close

Copy and save the link in order to return to this view