SwePub
Sök i LIBRIS databas

  Utökad sökning

WFRF:(Olofsson Thomas 1968 )
 

Sökning: WFRF:(Olofsson Thomas 1968 ) > Energy evaluation o...

  • Allard, Ingrid,1986-Umeå universitet,Institutionen för tillämpad fysik och elektronik (författare)

Energy evaluation of residential buildings : Performance gap analysis incorporating uncertainties in the evaluation methods

  • Artikel/kapitelEngelska2018

Förlag, utgivningsår, omfång ...

  • 2018-03-20
  • Tsinghua University Press,2018
  • printrdacarrier

Nummerbeteckningar

  • LIBRIS-ID:oai:DiVA.org:umu-150666
  • https://urn.kb.se/resolve?urn=urn:nbn:se:umu:diva-150666URI
  • https://doi.org/10.1007/s12273-018-0439-7DOI

Kompletterande språkuppgifter

  • Språk:engelska
  • Sammanfattning på:engelska

Ingår i deldatabas

Klassifikation

  • Ämneskategori:ref swepub-contenttype
  • Ämneskategori:art swepub-publicationtype

Anmärkningar

  • Originally included in thesis in manuscript form with title A methodology to investigate the building energy performance gap
  • Calculation and measurement-based energy performance evaluations of the same building often provide different results. This difference is referred as "the performance gap". However, a large performance gap may not necessarily mean that there are flaws in the building or deviations from the intended design. The causes for the performance gap can be analysed by calibrating the simulation model to measured data. In this paper, an approach is introduced for verifying compliance with energy performance criteria of residential buildings. The approach is based on a performance gap analysis that takes the uncertainties in the energy evaluation methods into consideration. The scope is to verify building energy performance through simulation and analysis of measured data, identifying any performance gap due to deviations from the intended design or flaws in the finished building based on performance gap analysis. In the approach, a simulation model is calibrated to match the heat loss coefficient of the building envelope [kWh/K] instead of the measured energy. The introduced approach is illustrated using a single-family residential building. The heat loss coefficient was found useful towards identifying any deviations from the intended design or flaws in the finished building. The case study indicated that the method uncertainty was important to consider in the performance gap analysis and that the proposed approach is applicable even when the performance gap appears to be non-existing.

Ämnesord och genrebeteckningar

Biuppslag (personer, institutioner, konferenser, titlar ...)

  • Olofsson, Thomas,1968-Umeå universitet,Institutionen för tillämpad fysik och elektronik(Swepub:umu)thol0001 (författare)
  • Nair, GireeshUmeå universitet,Institutionen för tillämpad fysik och elektronik(Swepub:umu)gigo0003 (författare)
  • Umeå universitetInstitutionen för tillämpad fysik och elektronik (creator_code:org_t)

Sammanhörande titlar

  • Ingår i:Building Simulation: Tsinghua University Press11:4, s. 725-7371996-35991996-8744

Internetlänk

Hitta via bibliotek

Till lärosätets databas

Hitta mer i SwePub

Av författaren/redakt...
Allard, Ingrid, ...
Olofsson, Thomas ...
Nair, Gireesh
Om ämnet
TEKNIK OCH TEKNOLOGIER
TEKNIK OCH TEKNO ...
och Maskinteknik
och Energiteknik
Artiklar i publikationen
Building Simulat ...
Av lärosätet
Umeå universitet

Sök utanför SwePub

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Stäng

Kopiera och spara länken för att återkomma till aktuell vy