SwePub
Sök i LIBRIS databas

  Utökad sökning

L773:0018 9294 OR L773:1558 2531
 

Sökning: L773:0018 9294 OR L773:1558 2531 > (2015-2019) > Robust Methods for ...

Robust Methods for Automated Selection of Cardiac Signals After Blind Source Separation

Wedekind, Daniel (författare)
Institute of Biomedical Engineering, TU Dresden, Dresden Germany
Kleyko, Denis (författare)
Luleå tekniska universitet,Datavetenskap
Osipov, Evgeny (författare)
Luleå tekniska universitet,Datavetenskap
visa fler...
Malberg, Hagen (författare)
Institute of Biomedical Engineering, TU Dresden, Dresden Germany
Zaunseder, Sebastian (författare)
Institute of Biomedical Engineering, TU Dresden, Dresden Germany
Wiklund, Urban (författare)
Umeå universitet,Radiofysik,Department of Biomedical Engineering and Informatics, Umea Universitet
visa färre...
 (creator_code:org_t)
Institute of Electrical and Electronics Engineers (IEEE), 2018
2018
Engelska.
Ingår i: IEEE Transactions on Biomedical Engineering. - : Institute of Electrical and Electronics Engineers (IEEE). - 0018-9294 .- 1558-2531. ; 65:10, s. 2248-2258
  • Tidskriftsartikel (refereegranskat)
Abstract Ämnesord
Stäng  
  • Objective: Novel minimum-contact vital signs monitoring techniques like textile or capacitive electrocardiogram (ECG) provide new opportunities for health monitoring. These techniques are sensitive to artifacts and require handling of unstable signal quality. Spatio-temporal blind source separation (BSS) is capable of processing suchlike multichannel signals. However, BSS's permutation indeterminacy requires the selection of the cardiac signal (i.e., the component resembling the electric cardiac activity) after its separation from artifacts. This study evaluates different concepts for solving permutation indeterminacy.Methods: Novel automated component selection routines based on heartbeat detections are compared with standard concepts, as using higher order moments or frequency-domain features, for solving permutation indeterminacy in spatio-temporal BSS. BSS was applied to a textile and a capacitive ECG dataset of healthy subjects performing a motion protocol, and to the MIT-BIH Arrhythmia Database. The performance of the subsequent component selection was evaluated by means of the heartbeat detection accuracy (ACC) using an automatically selected single component.Results: The proposed heartbeat-detection-based selection routines significantly outperformed the standard selectors based on Skewness, Kurtosis, and frequency-domain features, especially for datasets containing motion artifacts. For arrhythmia data, beat analysis by sparse coding outperformed simple periodicity tests of the detected heartbeats. Conclusion: Component selection routines based on heartbeat detections are capable of reliably selecting cardiac signals after spatio-temporal BSS in case of severe motion artifacts and arrhythmia.Significance: The availability of robust cardiac component selectors for solving permutation indeterminacy facilitates the usage of spatio-temporal BSS to extract cardiac signals in artifact-sensitive minimum-contact vital signs monitoring techniques.

Ämnesord

NATURVETENSKAP  -- Data- och informationsvetenskap -- Datavetenskap (hsv//swe)
NATURAL SCIENCES  -- Computer and Information Sciences -- Computer Sciences (hsv//eng)

Nyckelord

Biomedical signal processing
blind source separation
cardiac signals
electrocardiogram
dependent component analysis
permutation indeterminacy
sparse coding
spatio-temporal processing
Dependable Communication and Computation Systems

Publikations- och innehållstyp

ref (ämneskategori)
art (ämneskategori)

Hitta via bibliotek

Till lärosätets databas

Sök utanför SwePub

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Stäng

Kopiera och spara länken för att återkomma till aktuell vy