Sökning: L773:2169 3536 OR L773:2169 3536 > (2015-2019) > Assessment of Blood...

  • Asan, Noor Badariah,1984-Uppsala universitet,Fasta tillståndets elektronik,Univ Tekn Malaysia Melaka, Fac Elect & Comp Engn, Durian Tunggal 76100, Malaysia (författare)

Assessment of Blood Vessel Effect on Fat-Intrabody Communication Using Numerical and Ex-Vivo Models at 2.45 GHZ

  • Artikel/kapitelEngelska2019

Förlag, utgivningsår, omfång ...

  • IEEE-INST ELECTRICAL ELECTRONICS ENGINEERS INC,2019
  • electronicrdacarrier

Nummerbeteckningar

  • LIBRIS-ID:oai:DiVA.org:umu-162027
  • https://urn.kb.se/resolve?urn=urn:nbn:se:umu:diva-162027URI
  • https://doi.org/10.1109/ACCESS.2019.2926646DOI
  • https://urn.kb.se/resolve?urn=urn:nbn:se:uu:diva-392068URI

Kompletterande språkuppgifter

  • Språk:engelska
  • Sammanfattning på:engelska

Ingår i deldatabas

Klassifikation

  • Ämneskategori:ref swepub-contenttype
  • Ämneskategori:art swepub-publicationtype

Anmärkningar

  • The potential offered by the intra-body communication (IBC) over the past few years has resulted in a spike of interest for the topic, specifically for medical applications. Fat-IBC is subsequently a novel alternative technique that utilizes fat tissue as a communication channel. This work aimed to identify such transmission medium and its performance in varying blood-vessel systems at 2.45 GHz, particularly in the context of the IBC and medical applications. It incorporated three-dimensional (3D) electromagnetic simulations and laboratory investigations that implemented models of blood vessels of varying orientations, sizes, and positions. Such investigations were undertaken by using ex-vivo porcine tissues and three blood-vessel system configurations. These configurations represent extreme cases of real-life scenarios that sufficiently elucidated their principal influence on the transmission. The blood-vessel models consisted of ex-vivo muscle tissues and copper rods. The results showed that the blood vessels crossing the channel vertically contributed to 5.1 dB and 17.1 dB signal losses for muscle and copper rods, respectively, which is the worst-case scenario in the context of fat-channel with perturbance. In contrast, blood vessels aligned-longitudinally in the channel have less effect and yielded 4.5 dB and 4.2 dB signal losses for muscle and copper rods, respectively. Meanwhile, the blood vessels crossing the channel horizontally displayed 3.4 dB and 1.9 dB signal losses for muscle and copper rods, respectively, which were the smallest losses among the configurations. The laboratory investigations were in agreement with the simulations. Thus, this work substantiated the fat-IBC signal transmission variability in the context of varying blood vessel configurations.

Ämnesord och genrebeteckningar

Biuppslag (personer, institutioner, konferenser, titlar ...)

  • Hassan, EmadeldeenUmeå universitet,Institutionen för datavetenskap,Umea Univ, Dept Comp Sci, S-90187 Umea, Sweden;Menoufia Univ, Dept Elect & Elect Commun, Menoufia 32952, Egypt(Swepub:umu)emha0068 (författare)
  • Perez, Mauricio DavidUppsala universitet,Fasta tillståndets elektronik(Swepub:uu)mauda437 (författare)
  • Shah, Syaiful Redzwan MohdUppsala universitet,Fasta tillståndets elektronik(Swepub:uu)syamo465 (författare)
  • Velander, JacobUppsala universitet,Fasta tillståndets elektronik(Swepub:uu)jacve939 (författare)
  • Blokhuis, Taco J.Maastricht Univ, Dept Surg, Med Ctr, NL-6229 HX Maastricht, Netherlands (författare)
  • Voigt, ThiemoUppsala universitet,Datorarkitektur och datorkommunikation,¨(Swepub:uu)thvoi765 (författare)
  • Augustine, Robin,1982-Uppsala universitet,Fasta tillståndets elektronik(Swepub:uu)robau345 (författare)
  • Uppsala universitetFasta tillståndets elektronik (creator_code:org_t)

Sammanhörande titlar

  • Ingår i:IEEE Access: IEEE-INST ELECTRICAL ELECTRONICS ENGINEERS INC7, s. 89886-899002169-3536