SwePub
Sök i LIBRIS databas

  Utökad sökning

L773:2049 4394
 

Sökning: L773:2049 4394 > A randomized double...

A randomized double-blind noninferiority trial, evaluating migration of a cemented vitamin E-stabilized highly crosslinked component compared with a standard polyethylene component in reverse hybrid total hip arthroplasty

Sköldenberg, Olof G. (författare)
Karolinska Institutet
Rysinska, Agata D. (författare)
Chammout, Ghaz (författare)
visa fler...
Salemyr, Mats (författare)
Mukka, Sebastian (författare)
Umeå universitet,Ortopedi
Bodén, Henrik (författare)
Eisler, Thomas (författare)
Karolinska Institutet
visa färre...
 (creator_code:org_t)
The British Editorial Society of Bone & Joint Surgery, 2019
2019
Engelska.
Ingår i: The Bone & Joint Journal. - : The British Editorial Society of Bone & Joint Surgery. - 2049-4394 .- 2049-4408. ; 101-B:10, s. 1192-1198
  • Tidskriftsartikel (refereegranskat)
Abstract Ämnesord
Stäng  
  • AIMS: Radiostereometric analysis (RSA) studies of vitamin E-doped, highly crosslinked polyethylene (VEPE) liners show low head penetration rates in cementless acetabular components. There is, however, currently no data on cemented VEPE acetabular components in total hip arthroplasty (THA). The aim of this study was to evaluate the safety of a new cemented VEPE component, compared with a conventional polyethylene (PE) component regarding migration, head penetration, and clinical results.PATIENTS AND METHODS: We enrolled 42 patients (21 male, 21 female) with osteoarthritis and a mean age of 67 years (sd 5), in a double-blinded, noninferiority, randomized controlled trial. The subjects were randomized in a 1:1 ratio to receive a reverse hybrid THA with a cemented component of either argon-gas gamma-sterilized PE component (controls) or VEPE, with identical geometry. The primary endpoint was proximal implant migration of the component at two years postoperatively measured with RSA. Secondary endpoints included total migration of the component, penetration of the femoral head into the component, and patient-reported outcome measurements.RESULTS: In total, 19 control implants and 18 implants in the VEPE group were analyzed for the primary endpoint. We found a continuous proximal migration of the component in the VEPE group that was significantly higher with a difference at two years of a mean 0.21 mm (95% confidence interval (CI) 0.05 to 0.37; p = 0.013). The total migration was also significantly higher in the VEPE group, but femoral head penetration was lower. We found no difference in clinical outcomes between the groups.CONCLUSION: At two years, this cemented VEPE component, although having a low head penetration and excellent clinical results, failed to meet noninferiority compared with the conventional implant by a proximal migration above the proposed safety threshold of RSA. The early proximal migration pattern of the VEPE component is a reason for continued monitoring, although a specific threshold for proximal migration and risk for later failure cannot be defined and needs further study.

Ämnesord

MEDICIN OCH HÄLSOVETENSKAP  -- Klinisk medicin -- Ortopedi (hsv//swe)
MEDICAL AND HEALTH SCIENCES  -- Clinical Medicine -- Orthopaedics (hsv//eng)
MEDICIN OCH HÄLSOVETENSKAP  -- Medicinsk bioteknologi -- Biomaterialvetenskap (hsv//swe)
MEDICAL AND HEALTH SCIENCES  -- Medical Biotechnology -- Biomaterials Science (hsv//eng)
MEDICIN OCH HÄLSOVETENSKAP  -- Hälsovetenskap -- Hälso- och sjukvårdsorganisation, hälsopolitik och hälsoekonomi (hsv//swe)
MEDICAL AND HEALTH SCIENCES  -- Health Sciences -- Health Care Service and Management, Health Policy and Services and Health Economy (hsv//eng)

Nyckelord

Cemented component
Highly crosslinked polyethylene
Radiostereometry
Randomized clinical trial
Total hip arthroplasty
Vitamin E

Publikations- och innehållstyp

ref (ämneskategori)
art (ämneskategori)

Hitta via bibliotek

Till lärosätets databas

Sök utanför SwePub

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Stäng

Kopiera och spara länken för att återkomma till aktuell vy