SwePub
Sök i LIBRIS databas

  Utökad sökning

WFRF:(Ekblom Kim 1970 )
 

Sökning: WFRF:(Ekblom Kim 1970 ) > Evaluation of urine...

  • Ekblom, Kim,1970-Umeå universitet,Klinisk kemi,Department of Clinical Chemistry and Transfusion Medicine, Växjö Central Hospital, Växjö (författare)

Evaluation of urine dipsticks for quality control of residual erythrocytes and leukocytes in leukocyte-depleted donor plasma

  • Artikel/kapitelEngelska2020

Förlag, utgivningsår, omfång ...

  • 2019-11-26
  • Taylor & Francis,2020
  • printrdacarrier

Nummerbeteckningar

  • LIBRIS-ID:oai:DiVA.org:umu-166509
  • https://urn.kb.se/resolve?urn=urn:nbn:se:umu:diva-166509URI
  • https://doi.org/10.1080/00365513.2019.1692233DOI

Kompletterande språkuppgifter

  • Språk:engelska
  • Sammanfattning på:engelska

Ingår i deldatabas

Klassifikation

  • Ämneskategori:ref swepub-contenttype
  • Ämneskategori:art swepub-publicationtype

Anmärkningar

  • Currently used methodologies for quality control of residual leukocytes and erythrocytes in leukocyte-depleted plasma are either expensive or time-consuming. It has been proposed that urine dipsticks could be used as a screening method for residual erythrocytes. The aim was, therefore, to evaluate if urine dipsticks could be used to detect residual erythrocytes and also residual leukocytes in leukocyte-depleted plasma. Dilution series ranging over the decision limits for residual erythrocytes and leukocytes were prepared. Positive, negative and overall agreements, as well as the precision and joint frequency distributions, were calculated for five dipstick analyzers and their corresponding dipsticks. Twenty-four consecutive leukocyte-depleted donor plasma samples were also tested. None of the dipstick analyzers had both a high positive and a high negative agreement. Accordingly, none of the analyzers were able to discriminate between cell concentrations close to the decision limits. The inconsistency count revealed differences in precision between the dipstick analyzers. In the 24 consecutive donor samples, no significant correlation between the dipstick analyzers and the reference methods were found. In conclusion, urine dipsticks are not suitable for quality control of residual leukocytes and erythrocytes in leukocyte-depleted donor plasma.

Ämnesord och genrebeteckningar

Biuppslag (personer, institutioner, konferenser, titlar ...)

  • Petersson, Annika (författare)
  • Umeå universitetKlinisk kemi (creator_code:org_t)

Sammanhörande titlar

  • Ingår i:Scandinavian Journal of Clinical and Laboratory Investigation: Taylor & Francis80:1, s. 39-450036-55131502-7686

Internetlänk

Hitta via bibliotek

Till lärosätets databas

Hitta mer i SwePub

Av författaren/redakt...
Ekblom, Kim, 197 ...
Petersson, Annik ...
Om ämnet
MEDICIN OCH HÄLSOVETENSKAP
MEDICIN OCH HÄLS ...
och Klinisk medicin
och Klinisk laborato ...
Artiklar i publikationen
Scandinavian Jou ...
Av lärosätet
Umeå universitet

Sök utanför SwePub

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Stäng

Kopiera och spara länken för att återkomma till aktuell vy